[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC-G110 / prf-ie2024-panasonic-dc-g110-go-occ66@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC-G110 / prf-ie2024-panasonic-dc-g110-go-occ66@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Image Engineering GmbH & Co. KG; Image Engineering spectral sensitivities workbook (April 2024); src-ie-202404-private; Image Engineering GmbH & Co. KG, Spectral sensitivities workbook (April 2024).; https://image-engineering.de/ Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:380-755,green:380-755,blue:380-755. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=177; documented-gap samples omitted=0; partial channels=red,green,blue. Shared normalization divisor=1 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        380,
        385,
        390,
        395,
        400,
        405,
        410,
        415,
        420,
        425,
        430,
        435,
        440,
        445,
        450,
        455,
        460,
        465,
        470,
        475,
        480,
        485,
        490,
        495,
        500,
        505,
        510,
        515,
        520,
        525,
        530,
        535,
        540,
        545,
        550,
        555,
        560,
        565,
        570,
        575,
        580,
        585,
        590,
        595,
        600,
        605,
        610,
        615,
        620,
        625,
        630,
        635,
        640,
        645,
        650,
        655,
        660,
        665,
        670,
        675,
        680,
        685,
        690,
        695,
        700,
        705,
        710,
        715,
        720,
        725,
        730,
        735,
        740,
        745,
        750,
        755
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0252,
        0.0149,
        0.0047,
        0.0036,
        0.0025,
        0.0026,
        0.0027,
        0.0094,
        0.016,
        0.0319,
        0.0462,
        0.0456,
        0.0449,
        0.0407,
        0.0371,
        0.0366,
        0.0369,
        0.0403,
        0.0436,
        0.0467,
        0.0489,
        0.0471,
        0.0454,
        0.0477,
        0.05,
        0.0548,
        0.0596,
        0.0779,
        0.0948,
        0.1097,
        0.1247,
        0.1011,
        0.0806,
        0.0648,
        0.0518,
        0.0496,
        0.0473,
        0.0576,
        0.071,
        0.222,
        0.3921,
        0.5908,
        0.7496,
        0.7487,
        0.7478,
        0.7034,
        0.6301,
        0.5891,
        0.5542,
        0.511,
        0.4709,
        0.4429,
        0.415,
        0.3653,
        0.3156,
        0.274,
        0.2344,
        0.1882,
        0.1421,
        0.096,
        0.0581,
        0.0323,
        0.0108,
        0.0063,
        0.0027,
        0.0022,
        0.0018,
        0.0014,
        0.0011,
        0.0009,
        0.0008,
        0.0008,
        0.0008,
        0.0009,
        0.0009,
        0.001
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC-G110 / prf-ie2024-panasonic-dc-g110-go-occ66@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC-G110 / prf-ie2024-panasonic-dc-g110-go-occ66@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Image Engineering GmbH & Co. KG; Image Engineering spectral sensitivities workbook (April 2024); src-ie-202404-private; Image Engineering GmbH & Co. KG, Spectral sensitivities workbook (April 2024).; https://image-engineering.de/ Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:380-755,green:380-755,blue:380-755. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=177; documented-gap samples omitted=0; partial channels=red,green,blue. Shared normalization divisor=1 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        380,
        385,
        390,
        395,
        400,
        405,
        410,
        415,
        420,
        425,
        430,
        435,
        440,
        445,
        450,
        455,
        460,
        465,
        470,
        475,
        480,
        485,
        490,
        495,
        500,
        505,
        510,
        515,
        520,
        525,
        530,
        535,
        540,
        545,
        550,
        555,
        560,
        565,
        570,
        575,
        580,
        585,
        590,
        595,
        600,
        605,
        610,
        615,
        620,
        625,
        630,
        635,
        640,
        645,
        650,
        655,
        660,
        665,
        670,
        675,
        680,
        685,
        690,
        695,
        700,
        705,
        710,
        715,
        720,
        725,
        730,
        735,
        740,
        745,
        750,
        755
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0489,
        0.03,
        0.0111,
        0.0089,
        0.0066,
        0.0044,
        0.0023,
        0.0111,
        0.02,
        0.0503,
        0.083,
        0.1038,
        0.1245,
        0.1346,
        0.1471,
        0.1695,
        0.1987,
        0.2552,
        0.3098,
        0.3563,
        0.3977,
        0.4184,
        0.439,
        0.515,
        0.5909,
        0.655,
        0.7191,
        0.8209,
        0.8998,
        0.9446,
        0.9893,
        0.9906,
        0.9768,
        0.9401,
        0.907,
        0.8877,
        0.8685,
        0.7766,
        0.6666,
        0.5924,
        0.5185,
        0.4448,
        0.3719,
        0.3022,
        0.2326,
        0.17,
        0.1122,
        0.0842,
        0.0656,
        0.0544,
        0.0446,
        0.0405,
        0.0364,
        0.0313,
        0.0262,
        0.0235,
        0.0213,
        0.019,
        0.0159,
        0.0116,
        0.0078,
        0.0047,
        0.002,
        0.0013,
        0.0007,
        0.0007,
        0.0006,
        0.0004,
        0.0003,
        0.0003,
        0.0003,
        0.0003,
        0.0003,
        0.0003,
        0.0004,
        0.0003
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC-G110 / prf-ie2024-panasonic-dc-g110-go-occ66@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic DC-G110 / prf-ie2024-panasonic-dc-g110-go-occ66@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Image Engineering GmbH & Co. KG; Image Engineering spectral sensitivities workbook (April 2024); src-ie-202404-private; Image Engineering GmbH & Co. KG, Spectral sensitivities workbook (April 2024).; https://image-engineering.de/ Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:380-755,green:380-755,blue:380-755. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=177; documented-gap samples omitted=0; partial channels=red,green,blue. Shared normalization divisor=1 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        380,
        385,
        390,
        395,
        400,
        405,
        410,
        415,
        420,
        425,
        430,
        435,
        440,
        445,
        450,
        455,
        460,
        465,
        470,
        475,
        480,
        485,
        490,
        495,
        500,
        505,
        510,
        515,
        520,
        525,
        530,
        535,
        540,
        545,
        550,
        555,
        560,
        565,
        570,
        575,
        580,
        585,
        590,
        595,
        600,
        605,
        610,
        615,
        620,
        625,
        630,
        635,
        640,
        645,
        650,
        655,
        660,
        665,
        670,
        675,
        680,
        685,
        690,
        695,
        700,
        705,
        710,
        715,
        720,
        725,
        730,
        735,
        740,
        745,
        750,
        755
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0,
        0,
        0,
        0,
        0.0022,
        0.0032,
        0.0042,
        0.0793,
        0.1543,
        0.3868,
        0.6258,
        0.733,
        0.8403,
        0.8662,
        0.8892,
        0.9004,
        0.9194,
        0.9699,
        1,
        0.9487,
        0.894,
        0.8252,
        0.7564,
        0.6696,
        0.5828,
        0.5122,
        0.4417,
        0.3635,
        0.2936,
        0.2362,
        0.1787,
        0.1473,
        0.1201,
        0.0991,
        0.0793,
        0.0641,
        0.0489,
        0.0365,
        0.0248,
        0.0211,
        0.0179,
        0.0155,
        0.0132,
        0.0113,
        0.0094,
        0.0078,
        0.0064,
        0.0059,
        0.0058,
        0.0061,
        0.0064,
        0.0069,
        0.0075,
        0.0085,
        0.0096,
        0.0101,
        0.0106,
        0.0096,
        0.008,
        0.0056,
        0.0035,
        0.002,
        0.0007,
        0.0004,
        0.0002,
        0.0002,
        0.0002,
        0.0002,
        0.0002,
        0.0002,
        0.0002,
        0.0002,
        0.0002,
        0.0002,
        0.0002,
        0.0002
      ],
      "range": 1
    }
  }
]
