[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic Lumix DC-GH5 II / prf-ie2024-panasonic-lumix-dc-gh5-ii-gl-occ65@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic Lumix DC-GH5 II / prf-ie2024-panasonic-lumix-dc-gh5-ii-gl-occ65@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Image Engineering GmbH & Co. KG; Image Engineering spectral sensitivities workbook (April 2024); src-ie-202404-private; Image Engineering GmbH & Co. KG, Spectral sensitivities workbook (April 2024).; https://image-engineering.de/ Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:380-755,green:380-755,blue:380-755. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=177; documented-gap samples omitted=0; partial channels=red,green,blue. Shared normalization divisor=1 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        380,
        385,
        390,
        395,
        400,
        405,
        410,
        415,
        420,
        425,
        430,
        435,
        440,
        445,
        450,
        455,
        460,
        465,
        470,
        475,
        480,
        485,
        490,
        495,
        500,
        505,
        510,
        515,
        520,
        525,
        530,
        535,
        540,
        545,
        550,
        555,
        560,
        565,
        570,
        575,
        580,
        585,
        590,
        595,
        600,
        605,
        610,
        615,
        620,
        625,
        630,
        635,
        640,
        645,
        650,
        655,
        660,
        665,
        670,
        675,
        680,
        685,
        690,
        695,
        700,
        705,
        710,
        715,
        720,
        725,
        730,
        735,
        740,
        745,
        750,
        755
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0272,
        0.0151,
        0.003,
        0.0025,
        0.0019,
        0.0019,
        0.0019,
        0.0137,
        0.0256,
        0.0461,
        0.0637,
        0.0604,
        0.0571,
        0.0524,
        0.0484,
        0.0472,
        0.0469,
        0.0502,
        0.0537,
        0.0583,
        0.0616,
        0.0592,
        0.0569,
        0.06,
        0.0631,
        0.0687,
        0.0743,
        0.0938,
        0.111,
        0.1248,
        0.1385,
        0.1128,
        0.0908,
        0.0742,
        0.0601,
        0.0563,
        0.0525,
        0.0644,
        0.0802,
        0.2276,
        0.3929,
        0.5853,
        0.7367,
        0.7245,
        0.7123,
        0.6683,
        0.603,
        0.5643,
        0.53,
        0.4871,
        0.4462,
        0.4131,
        0.38,
        0.3375,
        0.2949,
        0.255,
        0.2157,
        0.1652,
        0.1195,
        0.081,
        0.0491,
        0.0268,
        0.0084,
        0.0051,
        0.0024,
        0.002,
        0.0016,
        0.0011,
        0.0007,
        0.0006,
        0.0005,
        0.0005,
        0.0005,
        0.0005,
        0.0005,
        0.0006
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic Lumix DC-GH5 II / prf-ie2024-panasonic-lumix-dc-gh5-ii-gl-occ65@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic Lumix DC-GH5 II / prf-ie2024-panasonic-lumix-dc-gh5-ii-gl-occ65@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Image Engineering GmbH & Co. KG; Image Engineering spectral sensitivities workbook (April 2024); src-ie-202404-private; Image Engineering GmbH & Co. KG, Spectral sensitivities workbook (April 2024).; https://image-engineering.de/ Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:380-755,green:380-755,blue:380-755. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=177; documented-gap samples omitted=0; partial channels=red,green,blue. Shared normalization divisor=1 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        380,
        385,
        390,
        395,
        400,
        405,
        410,
        415,
        420,
        425,
        430,
        435,
        440,
        445,
        450,
        455,
        460,
        465,
        470,
        475,
        480,
        485,
        490,
        495,
        500,
        505,
        510,
        515,
        520,
        525,
        530,
        535,
        540,
        545,
        550,
        555,
        560,
        565,
        570,
        575,
        580,
        585,
        590,
        595,
        600,
        605,
        610,
        615,
        620,
        625,
        630,
        635,
        640,
        645,
        650,
        655,
        660,
        665,
        670,
        675,
        680,
        685,
        690,
        695,
        700,
        705,
        710,
        715,
        720,
        725,
        730,
        735,
        740,
        745,
        750,
        755
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0577,
        0.0345,
        0.0114,
        0.0091,
        0.0068,
        0.0047,
        0.0027,
        0.0192,
        0.0357,
        0.0773,
        0.1197,
        0.1407,
        0.1617,
        0.1747,
        0.1905,
        0.2169,
        0.2494,
        0.3057,
        0.362,
        0.4177,
        0.4661,
        0.4852,
        0.5042,
        0.5848,
        0.6653,
        0.7237,
        0.7822,
        0.8748,
        0.942,
        0.971,
        1,
        0.9929,
        0.977,
        0.9481,
        0.9171,
        0.8776,
        0.8382,
        0.7564,
        0.664,
        0.5956,
        0.5265,
        0.4561,
        0.3857,
        0.3145,
        0.2434,
        0.1813,
        0.1251,
        0.0962,
        0.0761,
        0.0638,
        0.0529,
        0.0475,
        0.0421,
        0.0365,
        0.0309,
        0.0275,
        0.0246,
        0.0207,
        0.0167,
        0.0123,
        0.0083,
        0.0049,
        0.0021,
        0.0014,
        0.0009,
        0.0009,
        0.0009,
        0.0007,
        0.0005,
        0.0004,
        0.0004,
        0.0004,
        0.0004,
        0.0004,
        0.0005,
        0.0005
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic Lumix DC-GH5 II / prf-ie2024-panasonic-lumix-dc-gh5-ii-gl-occ65@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic Lumix DC-GH5 II / prf-ie2024-panasonic-lumix-dc-gh5-ii-gl-occ65@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Image Engineering GmbH & Co. KG; Image Engineering spectral sensitivities workbook (April 2024); src-ie-202404-private; Image Engineering GmbH & Co. KG, Spectral sensitivities workbook (April 2024).; https://image-engineering.de/ Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:380-755,green:380-755,blue:380-755. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=177; documented-gap samples omitted=0; partial channels=red,green,blue. Shared normalization divisor=1 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        380,
        385,
        390,
        395,
        400,
        405,
        410,
        415,
        420,
        425,
        430,
        435,
        440,
        445,
        450,
        455,
        460,
        465,
        470,
        475,
        480,
        485,
        490,
        495,
        500,
        505,
        510,
        515,
        520,
        525,
        530,
        535,
        540,
        545,
        550,
        555,
        560,
        565,
        570,
        575,
        580,
        585,
        590,
        595,
        600,
        605,
        610,
        615,
        620,
        625,
        630,
        635,
        640,
        645,
        650,
        655,
        660,
        665,
        670,
        675,
        680,
        685,
        690,
        695,
        700,
        705,
        710,
        715,
        720,
        725,
        730,
        735,
        740,
        745,
        750,
        755
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0,
        0,
        0,
        0.0041,
        0.0041,
        0.0061,
        0.008,
        0.1046,
        0.2012,
        0.431,
        0.6564,
        0.7309,
        0.8054,
        0.8404,
        0.8703,
        0.8801,
        0.8927,
        0.9165,
        0.9319,
        0.9133,
        0.8855,
        0.821,
        0.7565,
        0.6831,
        0.6096,
        0.5379,
        0.4662,
        0.3893,
        0.32,
        0.2618,
        0.2037,
        0.1692,
        0.1397,
        0.1177,
        0.0963,
        0.0771,
        0.058,
        0.044,
        0.0313,
        0.0268,
        0.0229,
        0.0198,
        0.0168,
        0.0143,
        0.0118,
        0.0097,
        0.008,
        0.0076,
        0.0075,
        0.0079,
        0.0083,
        0.0087,
        0.0092,
        0.0104,
        0.0116,
        0.012,
        0.0122,
        0.0103,
        0.0083,
        0.0059,
        0.0038,
        0.0021,
        0.0007,
        0.0005,
        0.0003,
        0.0003,
        0.0003,
        0.0003,
        0.0003,
        0.0003,
        0.0003,
        0.0002,
        0.0003,
        0.0003,
        0.0003,
        0.0003
      ],
      "range": 1
    }
  }
]
