    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic S5 / prf-ie2024-panasonic-s5-gi-occ64@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic S5 / prf-ie2024-panasonic-s5-gi-occ64@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Image Engineering GmbH & Co. KG; Image Engineering spectral sensitivities workbook (April 2024); src-ie-202404-private; Image Engineering GmbH & Co. KG, Spectral sensitivities workbook (April 2024).; https://image-engineering.de/ Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:380-755,green:380-755,blue:380-755. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=177; documented-gap samples omitted=0; partial channels=red,green,blue. Shared normalization divisor=1 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        380,
        385,
        390,
        395,
        400,
        405,
        410,
        415,
        420,
        425,
        430,
        435,
        440,
        445,
        450,
        455,
        460,
        465,
        470,
        475,
        480,
        485,
        490,
        495,
        500,
        505,
        510,
        515,
        520,
        525,
        530,
        535,
        540,
        545,
        550,
        555,
        560,
        565,
        570,
        575,
        580,
        585,
        590,
        595,
        600,
        605,
        610,
        615,
        620,
        625,
        630,
        635,
        640,
        645,
        650,
        655,
        660,
        665,
        670,
        675,
        680,
        685,
        690,
        695,
        700,
        705,
        710,
        715,
        720,
        725,
        730,
        735,
        740,
        745,
        750,
        755
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.017,
        0.0097,
        0.0023,
        0.0016,
        0.001,
        0.0012,
        0.0014,
        0.0089,
        0.0164,
        0.0325,
        0.0495,
        0.0471,
        0.0447,
        0.0401,
        0.0363,
        0.0356,
        0.0356,
        0.0381,
        0.0406,
        0.0431,
        0.0448,
        0.0436,
        0.0423,
        0.0442,
        0.0461,
        0.0517,
        0.0574,
        0.0762,
        0.0921,
        0.1036,
        0.1152,
        0.0941,
        0.0762,
        0.0632,
        0.0502,
        0.0489,
        0.0477,
        0.064,
        0.0848,
        0.2273,
        0.4002,
        0.6185,
        0.79,
        0.7743,
        0.7585,
        0.711,
        0.6424,
        0.6049,
        0.5751,
        0.5258,
        0.4765,
        0.4293,
        0.3821,
        0.3447,
        0.3072,
        0.2574,
        0.2045,
        0.1386,
        0.085,
        0.0497,
        0.0244,
        0.0139,
        0.0052,
        0.0033,
        0.0017,
        0.0014,
        0.0011,
        0.0007,
        0.0005,
        0.0004,
        0.0004,
        0.0003,
        0.0003,
        0.0003,
        0.0003,
        0.0004
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic S5 / prf-ie2024-panasonic-s5-gi-occ64@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic S5 / prf-ie2024-panasonic-s5-gi-occ64@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Image Engineering GmbH & Co. KG; Image Engineering spectral sensitivities workbook (April 2024); src-ie-202404-private; Image Engineering GmbH & Co. KG, Spectral sensitivities workbook (April 2024).; https://image-engineering.de/ Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:380-755,green:380-755,blue:380-755. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=177; documented-gap samples omitted=0; partial channels=red,green,blue. Shared normalization divisor=1 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        380,
        385,
        390,
        395,
        400,
        405,
        410,
        415,
        420,
        425,
        430,
        435,
        440,
        445,
        450,
        455,
        460,
        465,
        470,
        475,
        480,
        485,
        490,
        495,
        500,
        505,
        510,
        515,
        520,
        525,
        530,
        535,
        540,
        545,
        550,
        555,
        560,
        565,
        570,
        575,
        580,
        585,
        590,
        595,
        600,
        605,
        610,
        615,
        620,
        625,
        630,
        635,
        640,
        645,
        650,
        655,
        660,
        665,
        670,
        675,
        680,
        685,
        690,
        695,
        700,
        705,
        710,
        715,
        720,
        725,
        730,
        735,
        740,
        745,
        750,
        755
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0447,
        0.0275,
        0.0102,
        0.0078,
        0.0054,
        0.0036,
        0.0018,
        0.0155,
        0.0292,
        0.0716,
        0.1246,
        0.1436,
        0.1625,
        0.1726,
        0.1862,
        0.2137,
        0.2476,
        0.3071,
        0.3627,
        0.4028,
        0.4397,
        0.4634,
        0.4871,
        0.5578,
        0.6286,
        0.6972,
        0.7659,
        0.8537,
        0.9207,
        0.9562,
        0.9917,
        1,
        0.9941,
        0.9667,
        0.9394,
        0.8947,
        0.85,
        0.7734,
        0.6888,
        0.6283,
        0.5619,
        0.4866,
        0.4105,
        0.3312,
        0.252,
        0.189,
        0.1369,
        0.1099,
        0.0892,
        0.0744,
        0.0596,
        0.0516,
        0.0437,
        0.0387,
        0.0337,
        0.0288,
        0.0239,
        0.0176,
        0.012,
        0.0075,
        0.0042,
        0.0025,
        0.0012,
        0.0009,
        0.0006,
        0.0005,
        0.0005,
        0.0004,
        0.0003,
        0.0002,
        0.0002,
        0.0002,
        0.0002,
        0.0002,
        0.0002,
        0.0002
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic S5 / prf-ie2024-panasonic-s5-gi-occ64@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Panasonic S5 / prf-ie2024-panasonic-s5-gi-occ64@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Image Engineering GmbH & Co. KG; Image Engineering spectral sensitivities workbook (April 2024); src-ie-202404-private; Image Engineering GmbH & Co. KG, Spectral sensitivities workbook (April 2024).; https://image-engineering.de/ Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:380-755,green:380-755,blue:380-755. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=177; documented-gap samples omitted=0; partial channels=red,green,blue. Shared normalization divisor=1 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        380,
        385,
        390,
        395,
        400,
        405,
        410,
        415,
        420,
        425,
        430,
        435,
        440,
        445,
        450,
        455,
        460,
        465,
        470,
        475,
        480,
        485,
        490,
        495,
        500,
        505,
        510,
        515,
        520,
        525,
        530,
        535,
        540,
        545,
        550,
        555,
        560,
        565,
        570,
        575,
        580,
        585,
        590,
        595,
        600,
        605,
        610,
        615,
        620,
        625,
        630,
        635,
        640,
        645,
        650,
        655,
        660,
        665,
        670,
        675,
        680,
        685,
        690,
        695,
        700,
        705,
        710,
        715,
        720,
        725,
        730,
        735,
        740,
        745,
        750,
        755
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0,
        0,
        0,
        0,
        0.0014,
        0.0038,
        0.0062,
        0.0871,
        0.168,
        0.3994,
        0.6798,
        0.7551,
        0.8305,
        0.8528,
        0.8739,
        0.8901,
        0.9049,
        0.9141,
        0.9145,
        0.8792,
        0.8394,
        0.7822,
        0.7249,
        0.6427,
        0.5606,
        0.4894,
        0.4182,
        0.3356,
        0.267,
        0.2195,
        0.1719,
        0.1427,
        0.1178,
        0.0992,
        0.0806,
        0.0609,
        0.0412,
        0.0305,
        0.0221,
        0.0193,
        0.0166,
        0.0143,
        0.012,
        0.01,
        0.008,
        0.0066,
        0.0057,
        0.0053,
        0.0051,
        0.0054,
        0.0057,
        0.0064,
        0.0071,
        0.0079,
        0.0088,
        0.0086,
        0.0081,
        0.0061,
        0.0042,
        0.0024,
        0.0012,
        0.0007,
        0.0003,
        0.0002,
        0.0001,
        0.0002,
        0.0002,
        0.0002,
        0.0002,
        0.0002,
        0.0002,
        0.0002,
        0.0002,
        0.0002,
        0.0002,
        0.0002
      ],
      "range": 1
    }
  }
]