[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Canon PowerShot G9 X / prf-solomatov-pred-canon-powershot-g9-x-f3893a2a90f0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Canon PowerShot G9 X / prf-solomatov-pred-canon-powershot-g9-x-f3893a2a90f0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000499434283019 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26470017; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.018654649003436604,
        0.029297821721247484,
        0.02528333022802293,
        0.0008992125158588053,
        0.000010619530752301917,
        0.0000020611667407190055,
        0.030483626297041957,
        0.06813029769863284,
        0.12153800389197582,
        0.12175092047329918,
        0.09819421627118712,
        0.06785537780053442,
        0.03337938965201501,
        0.000004078657372981664,
        0.000010251560074345414,
        0.000020752709411145856,
        0.000008830151447525378,
        0.19438353915544943,
        0.5281258153458998,
        0.6850515651830213,
        0.6617962120437374,
        0.5934566373224666,
        0.5065458005415298,
        0.44164861687944496,
        0.3837709145714753,
        0.31685902814261363,
        0.2540751055670407,
        0.1790570598954653,
        0.1037799112927079,
        0.039481212413581594,
        0.02912791631376738
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Canon PowerShot G9 X / prf-solomatov-pred-canon-powershot-g9-x-f3893a2a90f0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Canon PowerShot G9 X / prf-solomatov-pred-canon-powershot-g9-x-f3893a2a90f0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000499434283019 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26470017; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.02361195036255549,
        0.03769949839528377,
        0.07319944891394882,
        0.1190426982540898,
        0.1666604425576029,
        0.1976179027177974,
        0.24431979258054415,
        0.33521932107786606,
        0.44751887972594295,
        0.5655309629790427,
        0.7028595591759536,
        0.866100641562956,
        0.9719932846749122,
        1,
        0.9707871593399849,
        0.9031904822041412,
        0.8088066470236331,
        0.6733416310632755,
        0.5230281856455642,
        0.38896685641323586,
        0.29337081303473783,
        0.21725853499656228,
        0.16478941608391448,
        0.11252144709466251,
        0.07104816755973371,
        0.035751133123128005,
        0.01799682282261496,
        0.0031276177974746563,
        0.000021275842799354274,
        0.0032709576842072435,
        0.00042738487204490374
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Canon PowerShot G9 X / prf-solomatov-pred-canon-powershot-g9-x-f3893a2a90f0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Canon PowerShot G9 X / prf-solomatov-pred-canon-powershot-g9-x-f3893a2a90f0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000499434283019 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26470017; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06270642818249794,
        0.15225804553350064,
        0.35167837705006455,
        0.5794031377832792,
        0.7207877510138083,
        0.8045819313225223,
        0.8608390259883063,
        0.8519584027564212,
        0.7798003759624835,
        0.6497442038835479,
        0.48568077972900425,
        0.3344586139131845,
        0.21073223730253565,
        0.1271725892733654,
        0.0908983121040937,
        0.06579824637060111,
        0.05847561844352854,
        0.06591670671644906,
        0.07412465335714587,
        0.060074244616888095,
        0.030867718117949573,
        0.007117789702448226,
        0.000038510940327741015,
        0.000012793295403829803,
        0.00001549647699036234,
        0.000709063858931409,
        0.001721151733161472,
        0.00430186907181384,
        0.0024734844666836793,
        0.0001426386615883718,
        0.000801493408291243
      ],
      "range": 1
    }
  }
]
