[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm FinePix SL1000 / prf-solomatov-pred-fujifilm-finepix-sl1000-5ec52618d098@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm FinePix SL1000 / prf-solomatov-pred-fujifilm-finepix-sl1000-5ec52618d098@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000491549207547 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26052108; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.014358366144497788,
        0.03211725048478545,
        0.02908758679409158,
        0.000511269544689007,
        0.00012120920956499251,
        0.010880465104781538,
        0.0456574086559271,
        0.08476057096554988,
        0.1323425233958035,
        0.13804772327515175,
        0.12334165342781474,
        0.09934806126124716,
        0.07075382094283443,
        0.013553436443607556,
        0.00011480749529622195,
        0.00002730955586815051,
        0.000025502224440231202,
        0.24257728799769898,
        0.5932275197766378,
        0.7349623678456594,
        0.6921082259447104,
        0.6097757837396687,
        0.5169871276393821,
        0.4450544752066993,
        0.37945740021786334,
        0.3151785242808817,
        0.24750868295931905,
        0.16963484398726592,
        0.09317143312300463,
        0.0383371911757596,
        0.030643245123525946
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm FinePix SL1000 / prf-solomatov-pred-fujifilm-finepix-sl1000-5ec52618d098@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm FinePix SL1000 / prf-solomatov-pred-fujifilm-finepix-sl1000-5ec52618d098@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000491549207547 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26052108; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.024860862986595938,
        0.04298601470410669,
        0.0821623695022884,
        0.12663601446690592,
        0.17784668632363468,
        0.22177379529774197,
        0.2869764436853949,
        0.393356778522327,
        0.52130932888425,
        0.6386646488707656,
        0.7626842933401012,
        0.9031108278658068,
        0.9884857449775422,
        1,
        0.9628713104663302,
        0.889817360024623,
        0.79314370713714,
        0.6619121717891278,
        0.5258612331075486,
        0.3968167299584642,
        0.29471760800827834,
        0.21358680802965865,
        0.16022464397246694,
        0.11200317401241718,
        0.07533752990832833,
        0.04574756324753215,
        0.029374145369570764,
        0.014507719877202521,
        0.006548167048403868,
        0.005884718165163671,
        0.0022868903572574074
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm FinePix SL1000 / prf-solomatov-pred-fujifilm-finepix-sl1000-5ec52618d098@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm FinePix SL1000 / prf-solomatov-pred-fujifilm-finepix-sl1000-5ec52618d098@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000491549207547 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26052108; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06210222604635294,
        0.1459293643714209,
        0.3383309967341862,
        0.5605484360554944,
        0.6939280751903418,
        0.7711293526718751,
        0.8199111014439748,
        0.8066161552642636,
        0.7395688863258205,
        0.6327469155122432,
        0.4982356928660053,
        0.3793303428199948,
        0.27564968579952853,
        0.20158305807729646,
        0.15910731392353838,
        0.12378518397890034,
        0.09870233300451979,
        0.08792780344603773,
        0.0823438344122241,
        0.05601278966610732,
        0.022899697854264482,
        0.004247705079197807,
        0.0005201356983126576,
        0.00012802492251055107,
        0.0009080549109260179,
        0.004312682867971905,
        0.007043109716879723,
        0.005810673167997504,
        0.0024494421006952226,
        0.001403466695575507,
        0.0009911741279658224
      ],
      "range": 1
    }
  }
]
