[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100 IR / prf-solomatov-pred-fujifilm-gfx-100-ir-ed936f288b25@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100 IR / prf-solomatov-pred-fujifilm-gfx-100-ir-ed936f288b25@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26663753 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26663753; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.012000533833327965,
        0.023130937344041553,
        0.023488505162795346,
        0.000017499277014754823,
        0.0034426502525732217,
        0.023822810689852997,
        0.04908906109353773,
        0.07509400495871679,
        0.1102353970950751,
        0.10894749137527639,
        0.09445224758870216,
        0.07513636583717229,
        0.05940715097383328,
        0.022394158091698493,
        0.000123110568868531,
        0.00008227232678010481,
        0.0056314791844943955,
        0.2268511563244679,
        0.5839479161091838,
        0.7587497903989735,
        0.7270299871139669,
        0.6561221145425402,
        0.5638892619504838,
        0.49079024996968734,
        0.42041891102126544,
        0.3492932896580613,
        0.282093184706594,
        0.19751569105819425,
        0.11246437063829687,
        0.04499513253066813,
        0.03410291491974141
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100 IR / prf-solomatov-pred-fujifilm-gfx-100-ir-ed936f288b25@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100 IR / prf-solomatov-pred-fujifilm-gfx-100-ir-ed936f288b25@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26663753 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26663753; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.017476937698905324,
        0.029548893585985437,
        0.0610244364324857,
        0.09744151170317246,
        0.13892464800435256,
        0.17538493549651468,
        0.22978065765910746,
        0.3247358539512423,
        0.44245129333443795,
        0.5589137433128787,
        0.6975521412908378,
        0.8596508150971846,
        0.9663628372195018,
        1,
        0.9808056652790026,
        0.9202323468868017,
        0.8290707613440613,
        0.6917230293874984,
        0.5360008022876599,
        0.3942373003530298,
        0.28429932575508027,
        0.1987055985704638,
        0.14439940994052863,
        0.09713694842582737,
        0.062287810721918996,
        0.03337548168856799,
        0.017715480637703177,
        0.005395576534181066,
        0.0013959015821966249,
        0.004394793186090496,
        0.00016988506081645746
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100 IR / prf-solomatov-pred-fujifilm-gfx-100-ir-ed936f288b25@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100 IR / prf-solomatov-pred-fujifilm-gfx-100-ir-ed936f288b25@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26663753 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26663753; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.045631464557896254,
        0.11062148678019931,
        0.264279038288421,
        0.44881746391815136,
        0.5787100563075274,
        0.6656889598399744,
        0.7326829797740776,
        0.7480617225939649,
        0.7177890149222429,
        0.6324524158320848,
        0.5069766435355143,
        0.3821622184993988,
        0.26632961233926816,
        0.18203300188086802,
        0.1352512828932971,
        0.09769008511292465,
        0.07500903192435064,
        0.06834718653446871,
        0.0749226487359075,
        0.055123916726951376,
        0.01856347341651417,
        0.0001982606724567243,
        0.000013728006331291771,
        0.000025594157731659154,
        0.0030230238031382904,
        0.010837355866595373,
        0.015652800264088853,
        0.014170580188017793,
        0.007801823696761668,
        0.0018994006582644233,
        0.0014462810242804154
      ],
      "range": 1
    }
  }
]
