[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100 IR / prf-solomatov-pred-fujifilm-gfx-100-ir-ed936f288b25@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100 IR / prf-solomatov-pred-fujifilm-gfx-100-ir-ed936f288b25@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000503089679245 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26663753; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015900707329159554,
        0.029900967786200053,
        0.029640256514956033,
        0.00002156887632051176,
        0.004146828713326835,
        0.028057977034715752,
        0.05655913560777174,
        0.08468047367685086,
        0.12171825095914542,
        0.11784116414060508,
        0.1001193824440243,
        0.07808288998764963,
        0.060549596184868534,
        0.022394158091698493,
        0.00012083074351911376,
        0.00007928060580628282,
        0.005329792799610768,
        0.21093177693327717,
        0.5336075785135646,
        0.6815887947651795,
        0.6422098219506709,
        0.5700733126353218,
        0.48203436908670394,
        0.4128870356887846,
        0.34815941068948547,
        0.28480837464426534,
        0.22652937559771943,
        0.15624375561319845,
        0.08765605358573138,
        0.0345614786105132,
        0.025820778439232788
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100 IR / prf-solomatov-pred-fujifilm-gfx-100-ir-ed936f288b25@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100 IR / prf-solomatov-pred-fujifilm-gfx-100-ir-ed936f288b25@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000503089679245 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26663753; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.023156942451049555,
        0.03819735024529825,
        0.07700702692670815,
        0.12010232837832885,
        0.16734105327797014,
        0.20656447958478397,
        0.26474727947679777,
        0.36619149488118813,
        0.4885399697234419,
        0.6045393550118892,
        0.7394052697682879,
        0.8933626117676623,
        0.9849467379352613,
        1,
        0.9626425974034655,
        0.8867693524545543,
        0.784656256272058,
        0.6431810624129372,
        0.4897938365732065,
        0.3541453715035691,
        0.25113107108365423,
        0.17264584793827184,
        0.12343820527174222,
        0.08171838518363256,
        0.05158209325408917,
        0.027213854299909288,
        0.014226067784822249,
        0.004268142631516366,
        0.0010879821155356044,
        0.003375710708156467,
        0.00012862726033246067
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100 IR / prf-solomatov-pred-fujifilm-gfx-100-ir-ed936f288b25@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100 IR / prf-solomatov-pred-fujifilm-gfx-100-ir-ed936f288b25@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000503089679245 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26663753; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.060461690539212534,
        0.14299850730123326,
        0.33349497688776936,
        0.5531936183177214,
        0.6970825678249761,
        0.7840336638115255,
        0.8441782158266546,
        0.8435589637761731,
        0.7925587039766432,
        0.6840811844714387,
        0.5373952421476451,
        0.3971489721660419,
        0.2714513356534849,
        0.18203300188086802,
        0.13274662950638422,
        0.09413771838154558,
        0.07099069092840328,
        0.06355089274257618,
        0.06846379970694996,
        0.04951809468692242,
        0.016397734851254186,
        0.00017225927279026866,
        0.000011735231218684902,
        0.000021531593012348178,
        0.002503441586973897,
        0.008836613245070074,
        0.012569672939344079,
        0.011209563432312584,
        0.0060808331754171815,
        0.0014589599259132529,
        0.0010950413469551716
      ],
      "range": 1
    }
  }
]
