[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100S / prf-solomatov-pred-fujifilm-gfx-100s-1fc0b5cb2431@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100S / prf-solomatov-pred-fujifilm-gfx-100s-1fc0b5cb2431@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000487221018868 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.25822714; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.018062096377630947,
        0.02989466976867635,
        0.029853000918567456,
        0.00004723145605048907,
        0.00002702857250896527,
        0.008831110066724804,
        0.05400406427154555,
        0.09541825793781329,
        0.14508721694912988,
        0.13981990784689535,
        0.10671595433384733,
        0.06619316234536772,
        0.029836480409635307,
        0.00007461544514647065,
        0.000022473290016717096,
        0.00008343703327515175,
        0.00010307052619034766,
        0.15305651437301393,
        0.5358932002587948,
        0.728488964654942,
        0.6956920033011763,
        0.6182281601853746,
        0.529393906915164,
        0.4651238071884716,
        0.40874198728685135,
        0.3465562247610021,
        0.2834072201283371,
        0.2045531558685522,
        0.11508722736707463,
        0.04397144666142946,
        0.03190422996259362
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100S / prf-solomatov-pred-fujifilm-gfx-100s-1fc0b5cb2431@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100S / prf-solomatov-pred-fujifilm-gfx-100s-1fc0b5cb2431@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000487221018868 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.25822714; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.024186276953692784,
        0.041018375357824745,
        0.08175019702200384,
        0.13541947370578025,
        0.19117362184949405,
        0.23006331850151596,
        0.2773617890957482,
        0.36592458459699556,
        0.4729380409368796,
        0.585194459546944,
        0.7191393360124734,
        0.8735365192784287,
        0.9738312579263476,
        1,
        0.9720252057505996,
        0.9057062983035365,
        0.8144524961628743,
        0.6795278020629162,
        0.5207266075370964,
        0.3868689515565801,
        0.29126945370653134,
        0.21668990318838335,
        0.1632095221634421,
        0.11080809253975714,
        0.06651098845816517,
        0.030715079457089296,
        0.011421294405359326,
        0.000002000511780720035,
        0.000009236520465026621,
        0.002047749938852003,
        0.0005615723594573146
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100S / prf-solomatov-pred-fujifilm-gfx-100s-1fc0b5cb2431@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100S / prf-solomatov-pred-fujifilm-gfx-100s-1fc0b5cb2431@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000487221018868 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.25822714; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06426632121240239,
        0.15747334663130014,
        0.36223593619758093,
        0.5874740345551667,
        0.7243849859539092,
        0.8145931179469018,
        0.8752258590432539,
        0.8712639000934719,
        0.8083576407447594,
        0.6792232771726251,
        0.5196747886376312,
        0.3725759849240008,
        0.2494987567326013,
        0.16106030915263206,
        0.11713583472516712,
        0.08289914783761868,
        0.06284975817635369,
        0.0629434285794268,
        0.07463603461131424,
        0.056576150787905136,
        0.021397508036271218,
        0.001078837410414697,
        0.0009328428527515887,
        0.00004998847009910215,
        0.00011119819617672642,
        0.004864672658700041,
        0.009458782043004795,
        0.009235555409479778,
        0.005000217728970749,
        0.001213745261385894,
        0.001929259220058301
      ],
      "range": 1
    }
  }
]
