[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X A2 / prf-solomatov-pred-fujifilm-x-a2-732ae4fbc5a4@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X A2 / prf-solomatov-pred-fujifilm-x-a2-732ae4fbc5a4@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000503907358491 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2670709; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01657802492708865,
        0.029582370440062827,
        0.03331944652685325,
        0.00005621934313984579,
        0.013485631786098067,
        0.0380658109055602,
        0.06209245633145421,
        0.08433731076415177,
        0.11588369340001725,
        0.11057956222142372,
        0.09320335416550436,
        0.07541893997612839,
        0.06039141586920004,
        0.02834069679624399,
        0.00012101960676470666,
        0.0035746285622010004,
        0.03560222865913134,
        0.23384568496178224,
        0.5290693691682878,
        0.6663921979811227,
        0.6330955375520133,
        0.56171305993658,
        0.47350306241622747,
        0.40113470611783975,
        0.3331579027797487,
        0.2641022693570537,
        0.2013096523443888,
        0.13498101233702808,
        0.07340605539357438,
        0.02783972449024704,
        0.02050355055530198
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X A2 / prf-solomatov-pred-fujifilm-x-a2-732ae4fbc5a4@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X A2 / prf-solomatov-pred-fujifilm-x-a2-732ae4fbc5a4@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000503907358491 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2670709; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.022613093077531097,
        0.039012293383060635,
        0.07789568630509369,
        0.11883442631168917,
        0.1658931961683038,
        0.20578562138784537,
        0.26382355445851563,
        0.36794778369594305,
        0.49050882899135273,
        0.6075325094633397,
        0.7394429029894308,
        0.8919899782211757,
        0.983416684627421,
        1,
        0.9602946432188217,
        0.8839361076709661,
        0.7796954719835497,
        0.6376549421829395,
        0.48670337843001543,
        0.34837241562548066,
        0.24264888430999657,
        0.16328098888998277,
        0.11539320252267432,
        0.07731654231023499,
        0.049794107517423275,
        0.0282333092938127,
        0.01729893944176462,
        0.006855906019880025,
        0.003532817618401529,
        0.004301741944755581,
        0.0004312039205426617
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X A2 / prf-solomatov-pred-fujifilm-x-a2-732ae4fbc5a4@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X A2 / prf-solomatov-pred-fujifilm-x-a2-732ae4fbc5a4@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000503907358491 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2670709; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.05876909118514971,
        0.14410362703631754,
        0.3331022525514849,
        0.5479781707996414,
        0.6915957837753605,
        0.7894766412630919,
        0.8553948961965107,
        0.8646441147833538,
        0.821716766034787,
        0.7158327452006342,
        0.563611932262182,
        0.41290401706430907,
        0.2723395130137871,
        0.17185031016108457,
        0.11903214929346753,
        0.08122140497999866,
        0.06305232109846914,
        0.05749519657415631,
        0.05839380001392114,
        0.04223466667719308,
        0.017201506759690652,
        0.00082050601053325,
        0.0006320245201530935,
        0.0000070231267284847435,
        0.000014630753861849043,
        0.0036091762322865745,
        0.004778159730981435,
        0.005384741855931676,
        0.0026186074999736244,
        0.000032224519428350675,
        0.00024234695570138332
      ],
      "range": 1
    }
  }
]
