[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X T1 IR / prf-solomatov-pred-fujifilm-x-t1-ir-0e78ee3702ab@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X T1 IR / prf-solomatov-pred-fujifilm-x-t1-ir-0e78ee3702ab@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26457605 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26457605; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.010211705103315285,
        0.02082981660660517,
        0.025259956825268198,
        0.004543410108360148,
        0.02015565656830994,
        0.03541580955645834,
        0.05042095835960964,
        0.059419350315344115,
        0.07519363903119727,
        0.07091135800084701,
        0.05720173840375952,
        0.04475797412502001,
        0.03676971139300024,
        0.01827079397398215,
        0.00008807026561928036,
        0.0002022941607904419,
        0.04002624198222023,
        0.23010089537582862,
        0.5255387250660065,
        0.6972823503865901,
        0.6900703975284233,
        0.6352980173375481,
        0.5510080749939383,
        0.48563016191374836,
        0.4201955543595121,
        0.3494584638329887,
        0.2818255318272383,
        0.19706662791284396,
        0.11759034500666253,
        0.04563608837610207,
        0.03031028696663965
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X T1 IR / prf-solomatov-pred-fujifilm-x-t1-ir-0e78ee3702ab@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X T1 IR / prf-solomatov-pred-fujifilm-x-t1-ir-0e78ee3702ab@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26457605 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26457605; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.017059611026772833,
        0.027241632415330112,
        0.05647539148006783,
        0.09765550585549977,
        0.1366134803206866,
        0.16636412479512033,
        0.21371915560762209,
        0.3061510291653383,
        0.4207127591480786,
        0.5428223756458681,
        0.6863112137323087,
        0.8532816934866175,
        0.9660273482803904,
        1,
        0.9779721180356271,
        0.9137635095844843,
        0.8211581131398703,
        0.6888454189258627,
        0.5415529863719712,
        0.4052869486863985,
        0.2941068362007823,
        0.20864061580781784,
        0.1564632475237271,
        0.10921288982884127,
        0.0728647472059546,
        0.04324386882334966,
        0.02752579456832922,
        0.011058556887518731,
        0.005965865013103038,
        0.005496092333376358,
        0.0008463514743681448
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X T1 IR / prf-solomatov-pred-fujifilm-x-t1-ir-0e78ee3702ab@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X T1 IR / prf-solomatov-pred-fujifilm-x-t1-ir-0e78ee3702ab@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26457605 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26457605; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04851406240285165,
        0.12034686435147852,
        0.28263393455303304,
        0.4723613494116342,
        0.6128609524558251,
        0.7184199779231718,
        0.7990590985087275,
        0.8248364128196789,
        0.7984178084146316,
        0.690352811601806,
        0.5392682746605371,
        0.38805999258058316,
        0.2542134482694106,
        0.16094730418720818,
        0.12013075257567721,
        0.09033386430857972,
        0.07730697468648427,
        0.06677350803294553,
        0.05445521996416531,
        0.02989134882012185,
        0.00001433149372363825,
        0.000006189703489790553,
        0.000033532936938169576,
        0.00004817329648696471,
        0.000002527463842626723,
        0.00003115085435737664,
        0.00000978930405832274,
        0.0000026125898394809354,
        0.000013968276796028968,
        0.00001202188935846612,
        0.0014337876387526384
      ],
      "range": 1
    }
  }
]
