    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 5 Rear Ultra Wide Camera / prf-solomatov-pred-google-pixel-5-rear-ultra-wide-camera-341aa09b1a24@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 5 Rear Ultra Wide Camera / prf-solomatov-pred-google-pixel-5-rear-ultra-wide-camera-341aa09b1a24@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000501167490566 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26561877; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.017272744467569066,
        0.031732472592296064,
        0.03319663743033278,
        0.00006027708669800323,
        0.0025809941092710363,
        0.022454739717544976,
        0.05454851719808153,
        0.08655294306421095,
        0.12645215327466003,
        0.12861656030942545,
        0.11330631589025128,
        0.09599787422594346,
        0.0707344517743346,
        0.028388466673496003,
        0.0000829676646610367,
        0.00008812714115182309,
        0.01907859933053677,
        0.27187895723832434,
        0.5784352955332861,
        0.6905284426745156,
        0.645946826348153,
        0.5731914121462593,
        0.48507114222873,
        0.408511625126588,
        0.34499662688559246,
        0.27690576871622324,
        0.21218851352145396,
        0.14397680195859697,
        0.08017955577948846,
        0.03285456058325431,
        0.0254854348476309
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 5 Rear Ultra Wide Camera / prf-solomatov-pred-google-pixel-5-rear-ultra-wide-camera-341aa09b1a24@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 5 Rear Ultra Wide Camera / prf-solomatov-pred-google-pixel-5-rear-ultra-wide-camera-341aa09b1a24@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000501167490566 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26561877; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.024513117333537837,
        0.04064530373876008,
        0.0746611105726559,
        0.11776651508370788,
        0.1617356230989522,
        0.2039424471228278,
        0.2679655966920266,
        0.37965429735768186,
        0.5118113052590373,
        0.63319822877682,
        0.7620222923251997,
        0.9054834778696507,
        0.9890488971786953,
        1,
        0.9608502845666395,
        0.8832366772053866,
        0.7812370049052956,
        0.6408256141066716,
        0.4922837680692417,
        0.3594730642960235,
        0.25369469434207026,
        0.17517971931641163,
        0.12601705577824457,
        0.08648207550923273,
        0.054708802852580785,
        0.031355747996968046,
        0.02150225325042376,
        0.007637112263081566,
        0.003048269994137042,
        0.005021079641889481,
        0.000055307629158027615
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 5 Rear Ultra Wide Camera / prf-solomatov-pred-google-pixel-5-rear-ultra-wide-camera-341aa09b1a24@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 5 Rear Ultra Wide Camera / prf-solomatov-pred-google-pixel-5-rear-ultra-wide-camera-341aa09b1a24@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000501167490566 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26561877; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0597505835148623,
        0.14093542575708934,
        0.32407469646028697,
        0.5443336238169727,
        0.6821173143955698,
        0.7661939294090968,
        0.821183855539177,
        0.820344978039591,
        0.771002058074937,
        0.6740541778453875,
        0.5375855478888032,
        0.40904285343932256,
        0.28953826054768417,
        0.2010360186518445,
        0.14886007379562713,
        0.10610042841064693,
        0.07907699955520033,
        0.07700665057299054,
        0.08101187328715902,
        0.05705092276499658,
        0.023602962860393237,
        0.0005714189606231887,
        0.00004645068047300733,
        0.000025109788166020977,
        0.007805444434517936,
        0.015185729300913255,
        0.019124520363367304,
        0.01536073297832077,
        0.008159522668522259,
        0.003253095387996014,
        0.002919937999863489
      ],
      "range": 1
    }
  }
]