[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 7 Ultrawide Camera / prf-solomatov-pred-google-pixel-7-ultrawide-camera-4a729a8b4340@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 7 Ultrawide Camera / prf-solomatov-pred-google-pixel-7-ultrawide-camera-4a729a8b4340@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000498394528302 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2641491; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016619796224935084,
        0.030516002718383426,
        0.029656109804219333,
        0.0015558301009930852,
        0.000026908346632468352,
        0.00849815910786749,
        0.050910143502122564,
        0.09058403467603166,
        0.14404679276464186,
        0.148055192761843,
        0.12587321175805635,
        0.09661935693315096,
        0.0678346246786088,
        0.014970766131703648,
        0.00011603406028107834,
        0.0002230231328374082,
        0.011111657474617825,
        0.20437940860712855,
        0.5469835746762614,
        0.6965973448136498,
        0.6585496991408766,
        0.5857941321279734,
        0.49915647285762516,
        0.4315861160495498,
        0.374290074242161,
        0.3117831179436159,
        0.25024967694152256,
        0.1771254262849978,
        0.1017810484795942,
        0.037839718585812525,
        0.03140000936700414
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 7 Ultrawide Camera / prf-solomatov-pred-google-pixel-7-ultrawide-camera-4a729a8b4340@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 7 Ultrawide Camera / prf-solomatov-pred-google-pixel-7-ultrawide-camera-4a729a8b4340@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000498394528302 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2641491; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.02534011216581847,
        0.040381717066278834,
        0.07773941686721628,
        0.12456026759657839,
        0.1737447481881875,
        0.21493870267461318,
        0.2754665509810146,
        0.37979895977027867,
        0.5054546111457505,
        0.6234028950826234,
        0.7516259483753683,
        0.9004904041085946,
        0.9862443902967039,
        1,
        0.9605793288153742,
        0.8845950391447309,
        0.7880947418927957,
        0.6514766617022323,
        0.5020825725136766,
        0.3713104058481506,
        0.27113941330862,
        0.19364013472495423,
        0.14293780390720437,
        0.09693848302954296,
        0.06128309843522087,
        0.03362358650998476,
        0.019179313994645564,
        0.005581634551408966,
        0.002341316363728355,
        0.004656945361869325,
        0.00033286069685643446
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 7 Ultrawide Camera / prf-solomatov-pred-google-pixel-7-ultrawide-camera-4a729a8b4340@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 7 Ultrawide Camera / prf-solomatov-pred-google-pixel-7-ultrawide-camera-4a729a8b4340@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000498394528302 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2641491; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06590203269668532,
        0.14990289067248982,
        0.3411455418820009,
        0.5580943349005155,
        0.6893734026110115,
        0.7712328294049753,
        0.8244160227492072,
        0.8190129958598413,
        0.7656060677473442,
        0.6599171607309382,
        0.5200449950425725,
        0.39191531986899764,
        0.27826517063512757,
        0.19218437617239656,
        0.14256362669865308,
        0.099034977525262,
        0.07087845456275588,
        0.06797489511954063,
        0.07991341469255628,
        0.05979692658041632,
        0.02232858716283089,
        0.0006379248981159429,
        0.0003500460749067904,
        0.000021794448359080604,
        0.010375448415071261,
        0.01928288548457612,
        0.023422769186039246,
        0.019893482817429822,
        0.011679974324661158,
        0.004380068499850702,
        0.0051924529582507975
      ],
      "range": 1
    }
  }
]
