[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 7 Wide Camera / prf-solomatov-pred-google-pixel-7-wide-camera-be92315a3986@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 7 Wide Camera / prf-solomatov-pred-google-pixel-7-wide-camera-be92315a3986@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000500652584906 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26534587; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016835175237511706,
        0.029263569974337048,
        0.028775362313417763,
        0.000014368215875605923,
        0.000004589657444931299,
        0.008766976717762536,
        0.04545780028616007,
        0.07793023249401068,
        0.1268568053273262,
        0.12561602118989615,
        0.10340098016223127,
        0.07754895015723752,
        0.05581054238031639,
        0.015973162499193977,
        0.00012411386218576055,
        0.00015902406840482644,
        0.0005616237356549021,
        0.2090972820135709,
        0.5304813214489478,
        0.6821845485756869,
        0.6477665546480901,
        0.5738222448568175,
        0.4846606613425326,
        0.4152178162728242,
        0.3497608620566622,
        0.28141522841634814,
        0.21935113376455578,
        0.14855697359444517,
        0.08290285358058722,
        0.03037542447818242,
        0.02368366023021737
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 7 Wide Camera / prf-solomatov-pred-google-pixel-7-wide-camera-be92315a3986@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 7 Wide Camera / prf-solomatov-pred-google-pixel-7-wide-camera-be92315a3986@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000500652584906 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26534587; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.023096874656462527,
        0.03780552079019752,
        0.07260818636805007,
        0.11408691580627413,
        0.1583422183349535,
        0.19171897418263945,
        0.24635447427294732,
        0.35038715335027903,
        0.4755778318376189,
        0.5956055315998839,
        0.7315026648049959,
        0.8890070673626471,
        0.9837870677414928,
        1,
        0.9630067423014795,
        0.8858797764593058,
        0.786035518741741,
        0.6480891511487358,
        0.49488502204363655,
        0.35931731801942957,
        0.2561964867463989,
        0.17897538050688458,
        0.13038153962794347,
        0.08843482198452073,
        0.05617353712015567,
        0.031000213303605483,
        0.018303827366786214,
        0.0066206216510560295,
        0.001768879253375094,
        0.0033661043433886742,
        0.00023363948936317938
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 7 Wide Camera / prf-solomatov-pred-google-pixel-7-wide-camera-be92315a3986@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 7 Wide Camera / prf-solomatov-pred-google-pixel-7-wide-camera-be92315a3986@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000500652584906 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26534587; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06378729175245879,
        0.14925342332788008,
        0.3404903166034365,
        0.5628141110825972,
        0.7075622383995377,
        0.7977393924055088,
        0.8590520086432687,
        0.8625762340924913,
        0.8117223977645981,
        0.6977596317237282,
        0.5473504147624383,
        0.4034573803912725,
        0.2764040534659972,
        0.18659679911354943,
        0.14124260256720506,
        0.10418007458443852,
        0.08838737161372492,
        0.08672654747926718,
        0.09318466439604878,
        0.07304619790088834,
        0.040693667853206085,
        0.015600698111919945,
        0.002103854435284299,
        0.002165172177875221,
        0.00544098640130521,
        0.009495595558413571,
        0.011216433377038327,
        0.009348291429552154,
        0.005556140645902693,
        0.0010609614390717918,
        0.0016564108454265479
      ],
      "range": 1
    }
  }
]
