[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / GR / prf-solomatov-pred-gr-5558d7510726@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / GR / prf-solomatov-pred-gr-5558d7510726@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000537235660377 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2847349; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011403828341731204,
        0.025059816058769738,
        0.03341566731186163,
        0.011240647614390102,
        0.042575974577181666,
        0.058485643546564416,
        0.06850156332296706,
        0.07168240195772096,
        0.07898174202272593,
        0.0697982105818573,
        0.056678672407211056,
        0.04792910342423157,
        0.048246636203062514,
        0.04580039889736032,
        0.043667501283162366,
        0.05655081519367984,
        0.10034163984012597,
        0.22198595649078146,
        0.38821196306725525,
        0.4792222615206791,
        0.45870642657433275,
        0.40957713504794785,
        0.34219369037542435,
        0.2786379702775269,
        0.21914684501267667,
        0.16550739923076083,
        0.11897663469359807,
        0.07615088343264025,
        0.04170741709321237,
        0.01742456013788895,
        0.008996272026064544
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / GR / prf-solomatov-pred-gr-5558d7510726@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / GR / prf-solomatov-pred-gr-5558d7510726@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000537235660377 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2847349; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.019602291464797604,
        0.03382751038023738,
        0.06355942208164925,
        0.10810168302858814,
        0.1454661060484363,
        0.1693616787638841,
        0.2181420070571517,
        0.3130003643628108,
        0.4247412885927694,
        0.5392159951203017,
        0.6890324438626948,
        0.8627840024762213,
        0.9730409692556937,
        1,
        0.9628772243416075,
        0.88035346051873,
        0.7653427037370049,
        0.6161112090887766,
        0.4567855107474986,
        0.3098184608721174,
        0.19304492295582076,
        0.11155270013627688,
        0.07098705208746575,
        0.043870789151258804,
        0.0261832634166904,
        0.011483936110396019,
        0.012352886922984405,
        0.0040690367431223,
        0.000018935709197242352,
        0.0030790020695629916,
        0.00004636463842582797
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / GR / prf-solomatov-pred-gr-5558d7510726@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / GR / prf-solomatov-pred-gr-5558d7510726@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000537235660377 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2847349; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06032170309997123,
        0.14404910690182512,
        0.3326077208760048,
        0.546435786655473,
        0.6915535484218669,
        0.7913962121725623,
        0.8734228712849864,
        0.9028583900472169,
        0.8843481735115716,
        0.7671259347783872,
        0.5919258594573408,
        0.40108067842314055,
        0.2231437301585007,
        0.09707724975055744,
        0.03897586407307028,
        0.0046170410377576404,
        0.0015421632449040441,
        0.01094253954030358,
        0.021625036681125327,
        0.021517028944276807,
        0.016181367832558167,
        0.009207254727461792,
        0.000059531834076471284,
        0.0034816508323612647,
        0.0017491582790035572,
        0.007172276052620822,
        0.003968518574273611,
        0.0048053069243256235,
        0.005133106103049455,
        0.000012220341681566488,
        0.005126087228104859
      ],
      "range": 1
    }
  }
]
