    "model": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI Honor 20 Pro Rear Main Camera / prf-solomatov-pred-huawei-honor-20-pro-rear-main-camera-2505a858d45f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI Honor 20 Pro Rear Main Camera / prf-solomatov-pred-huawei-honor-20-pro-rear-main-camera-2505a858d45f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000498896943396 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26441538; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.02021599377086159,
        0.03250671348996417,
        0.03430562304046366,
        0.00005926262843940717,
        0.000010758986451200726,
        0.01618355920815869,
        0.0559306066413219,
        0.08842418013464029,
        0.13451566094289474,
        0.1330967571260223,
        0.11390387283825927,
        0.0910892119370488,
        0.06839779712976897,
        0.0204479898257053,
        0.000029544090571377452,
        0.00006172585057784324,
        0.00015253053534285986,
        0.2583191620168423,
        0.599200490322566,
        0.7252224992050932,
        0.674169527632369,
        0.5887357028557263,
        0.4975943300687266,
        0.42248493849168517,
        0.3569005974969195,
        0.2879626320119154,
        0.2184520207973874,
        0.14450500335167465,
        0.0776052147126816,
        0.029735039442952183,
        0.025652191638776838
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI Honor 20 Pro Rear Main Camera / prf-solomatov-pred-huawei-honor-20-pro-rear-main-camera-2505a858d45f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI Honor 20 Pro Rear Main Camera / prf-solomatov-pred-huawei-honor-20-pro-rear-main-camera-2505a858d45f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000498896943396 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26441538; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0254689022817054,
        0.04145007526581482,
        0.07898695893523579,
        0.12241037673024076,
        0.16894097564493898,
        0.21136807969003588,
        0.27418379353168393,
        0.3865222181534575,
        0.5170124212643507,
        0.6356780921204898,
        0.7629990222202658,
        0.906032142810049,
        0.989829907601616,
        1,
        0.9646584049070963,
        0.8855637265605628,
        0.7858813861627221,
        0.6496476524065772,
        0.5010222082626469,
        0.3691029269097966,
        0.26292771497129513,
        0.18294186259042158,
        0.1324267419327975,
        0.09195275660351179,
        0.060878451631198614,
        0.036539317563379026,
        0.026004429321040485,
        0.012953615051698798,
        0.0069746044139739095,
        0.006194130750759977,
        0.0022272646264806105
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI Honor 20 Pro Rear Main Camera / prf-solomatov-pred-huawei-honor-20-pro-rear-main-camera-2505a858d45f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI Honor 20 Pro Rear Main Camera / prf-solomatov-pred-huawei-honor-20-pro-rear-main-camera-2505a858d45f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000498896943396 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26441538; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06309267458269636,
        0.14478606322684132,
        0.3315226622380503,
        0.5575683379442165,
        0.6938550409517853,
        0.7686242053443841,
        0.8160852024305224,
        0.8006145868397141,
        0.7296681054445472,
        0.6178332959084518,
        0.4846876758833015,
        0.36844490961272275,
        0.27114363509298256,
        0.20110938327414996,
        0.16470705500200872,
        0.13255455398863852,
        0.11195105527306534,
        0.1026490062055246,
        0.09721138345489483,
        0.06966451152779235,
        0.03785347906010612,
        0.015401251330201824,
        0.005335107269966794,
        0.003963635975707665,
        0.005734595541965071,
        0.005681935608575126,
        0.007681580982715357,
        0.005034032212114544,
        0.0028847119422923317,
        0.0010156511922340865,
        0.0013544675372946483
      ],
      "range": 1
    }
  }
]