[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI Honor 20 Pro Rear Wide Camera / prf-solomatov-pred-huawei-honor-20-pro-rear-wide-camera-6f8c8014b815@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI Honor 20 Pro Rear Wide Camera / prf-solomatov-pred-huawei-honor-20-pro-rear-wide-camera-6f8c8014b815@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26853663 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26853663; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.012829313453438363,
        0.02074865428973321,
        0.017503988189618673,
        0.00004643028774137815,
        0.00003661006693947116,
        0.00003086254936617027,
        0.01493967284835592,
        0.04374682515379745,
        0.08705450723798835,
        0.09454173905437036,
        0.08473462260995827,
        0.07366952508490182,
        0.0595990870966095,
        0.02911055374456736,
        0.00005629662888076014,
        0.00007741500293647091,
        0.027723201114127335,
        0.24202590164328794,
        0.5785343697803909,
        0.7466204145036005,
        0.7249851165556073,
        0.6572437436188873,
        0.5647098870645691,
        0.4902566923551547,
        0.4195656473383166,
        0.3409407498708835,
        0.27025091511724114,
        0.18910783232812597,
        0.10993474521520584,
        0.04183145517242843,
        0.03115768973491624
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI Honor 20 Pro Rear Wide Camera / prf-solomatov-pred-huawei-honor-20-pro-rear-wide-camera-6f8c8014b815@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI Honor 20 Pro Rear Wide Camera / prf-solomatov-pred-huawei-honor-20-pro-rear-wide-camera-6f8c8014b815@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26853663 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26853663; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01782416983485642,
        0.029186290153414077,
        0.05399172172526333,
        0.08744469236841172,
        0.12169231065422992,
        0.15039893440235694,
        0.20396814021237997,
        0.3059694463284208,
        0.4278727039957268,
        0.5508607522184217,
        0.6927963235406656,
        0.8567792036416038,
        0.965196181988282,
        1,
        0.9790503068426829,
        0.9158363237074957,
        0.8238544961259103,
        0.6894108263740406,
        0.536247550287646,
        0.3952948839791428,
        0.28413322979438593,
        0.19984138849139502,
        0.14775085618673325,
        0.10092558694878982,
        0.06457690706850683,
        0.036027129706662366,
        0.021152767873790626,
        0.006517669861277398,
        0.0028002295254841024,
        0.0052728817666327305,
        0.00030553950870687547
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI Honor 20 Pro Rear Wide Camera / prf-solomatov-pred-huawei-honor-20-pro-rear-wide-camera-6f8c8014b815@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI Honor 20 Pro Rear Wide Camera / prf-solomatov-pred-huawei-honor-20-pro-rear-wide-camera-6f8c8014b815@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26853663 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26853663; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.047794246915216,
        0.11334403801820257,
        0.26626099389122443,
        0.4524729680267455,
        0.5839644297316162,
        0.6698636606856949,
        0.7328618818222303,
        0.7452755700404821,
        0.7082143691160495,
        0.6205764181966534,
        0.4915221807914995,
        0.36406277236740475,
        0.250172760416335,
        0.16689826263180557,
        0.12677011698553003,
        0.09562024368891499,
        0.08130131073738431,
        0.07786241303467613,
        0.0848404852626623,
        0.06794357998757934,
        0.038092017465177846,
        0.01376734451460123,
        0.0006749614009828007,
        0.0008735849556166695,
        0.00638237249048668,
        0.010793600113325322,
        0.014006358462158404,
        0.012464131988250542,
        0.008579034450532876,
        0.0018242571600008536,
        0.004436501269864003
      ],
      "range": 1
    }
  }
]
