    "model": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI P30 Pro Rear Main Camera / prf-solomatov-pred-huawei-p30-pro-rear-main-camera-00e469b83f56@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI P30 Pro Rear Main Camera / prf-solomatov-pred-huawei-p30-pro-rear-main-camera-00e469b83f56@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000513617207547 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27221712; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.020107202111314677,
        0.03250112739096627,
        0.03136265639721705,
        0.00014059152325959345,
        0.00008868752441901058,
        0.000006802311037601163,
        0.00429571226724877,
        0.02612777428578007,
        0.06853180552775913,
        0.06634284052227075,
        0.058524078941104084,
        0.05839460989599687,
        0.056555134753634,
        0.03335387943271166,
        0.0001859726330054317,
        0.00012293417775554243,
        0.046022577033362204,
        0.29214206762859646,
        0.6026026754951571,
        0.7083604216307378,
        0.6573508994095106,
        0.5756932012428229,
        0.48507679778174045,
        0.41609401803272056,
        0.3445662704140357,
        0.2697568679453655,
        0.20514992246118124,
        0.13403608909407952,
        0.0698722467003761,
        0.028591345910131266,
        0.018017781961273103
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI P30 Pro Rear Main Camera / prf-solomatov-pred-huawei-p30-pro-rear-main-camera-00e469b83f56@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI P30 Pro Rear Main Camera / prf-solomatov-pred-huawei-p30-pro-rear-main-camera-00e469b83f56@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000513617207547 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27221712; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.024143992486585712,
        0.03776741673938123,
        0.0681743171109325,
        0.10027091968625702,
        0.13299864603065245,
        0.16094059264980184,
        0.20694097066150088,
        0.3033009256290902,
        0.4291058855274545,
        0.5506214529139424,
        0.6915303357849059,
        0.8577711056527233,
        0.9708193789744577,
        1,
        0.9652350905831402,
        0.8830395170657093,
        0.7732893107793621,
        0.654499851300328,
        0.540583389642341,
        0.40411276751739045,
        0.2733296923671321,
        0.1728213126345617,
        0.12763034290777797,
        0.11279060742932086,
        0.0934853255877147,
        0.07375903130898998,
        0.06837924637198248,
        0.04622049542385039,
        0.025197891344103218,
        0.017379474383419077,
        0.007809214329670796
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI P30 Pro Rear Main Camera / prf-solomatov-pred-huawei-p30-pro-rear-main-camera-00e469b83f56@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI P30 Pro Rear Main Camera / prf-solomatov-pred-huawei-p30-pro-rear-main-camera-00e469b83f56@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000513617207547 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27221712; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06145499417891131,
        0.14224415153717257,
        0.3324520069022216,
        0.5615837802645388,
        0.6923405111331722,
        0.7602149245180955,
        0.8034756370688351,
        0.7761691054208432,
        0.688051324619113,
        0.5609255215101829,
        0.4119100701675193,
        0.2838808896225133,
        0.1895498888760334,
        0.14340992219739893,
        0.1420167242481541,
        0.15266483346421816,
        0.16896766796455925,
        0.14697889813424372,
        0.09660510273868002,
        0.069650393624479,
        0.068886048754024,
        0.061722863105696246,
        0.03718169128875818,
        0.00006304669351190453,
        2.798115887926153e-7,
        0.000011288051294665648,
        0.00003382059467379524,
        0.00003079905936410602,
        0.000002575224101391177,
        0.000022029757088700033,
        6.662732380682009e-7
      ],
      "range": 1
    }
  }
]