[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI P30 Rear Main Camera / prf-solomatov-pred-huawei-p30-rear-main-camera-408c0945d11c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI P30 Rear Main Camera / prf-solomatov-pred-huawei-p30-rear-main-camera-408c0945d11c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000505941264151 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26814887; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.020079015529694377,
        0.03220911669827832,
        0.030293529610374015,
        0.0002839261465052499,
        0.00006050272241582548,
        0.0000010602570214904214,
        0.021348680224760483,
        0.0509937336023575,
        0.09310841578100504,
        0.09692691623583753,
        0.09002087638855237,
        0.083393466925923,
        0.06865612625209616,
        0.03443758685240777,
        0.0000012268330109150022,
        0.000006377968517671139,
        0.043187943044473764,
        0.2931471063004875,
        0.5951481695146843,
        0.7075612646039569,
        0.6657245096725561,
        0.5862113111113901,
        0.492954295343719,
        0.4136190958947661,
        0.3418469934257042,
        0.2662806358847778,
        0.19929385482660048,
        0.1301109676696526,
        0.06883750405687179,
        0.028650332626203423,
        0.020824660383614517
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI P30 Rear Main Camera / prf-solomatov-pred-huawei-p30-rear-main-camera-408c0945d11c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI P30 Rear Main Camera / prf-solomatov-pred-huawei-p30-rear-main-camera-408c0945d11c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000505941264151 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26814887; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.02406447123942756,
        0.03968374458670172,
        0.07099969177213993,
        0.10482821300147607,
        0.14110544689732846,
        0.1747829499834675,
        0.22901521586805898,
        0.3337353168227275,
        0.46703519112349795,
        0.5891256568922832,
        0.7246789419623509,
        0.8802890386239262,
        0.9799439422184801,
        1,
        0.964198074278941,
        0.8886775008090231,
        0.7880568916811025,
        0.6629609096317647,
        0.5344071675687027,
        0.4000916622122781,
        0.28550323308590986,
        0.19653784659025353,
        0.1469681117685642,
        0.10896780600872585,
        0.08270608633834631,
        0.05782185935056838,
        0.04651848221248867,
        0.02751083014045658,
        0.014640803764319862,
        0.011355833838099719,
        0.005786763758717846
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI P30 Rear Main Camera / prf-solomatov-pred-huawei-p30-rear-main-camera-408c0945d11c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / HUAWEI P30 Rear Main Camera / prf-solomatov-pred-huawei-p30-rear-main-camera-408c0945d11c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000505941264151 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26814887; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.059248913113077825,
        0.13675839378363802,
        0.3211970997055976,
        0.5504226569680196,
        0.6869865447570903,
        0.760654567243437,
        0.8080799669228514,
        0.7904531205513928,
        0.7155136389349692,
        0.6029202725930503,
        0.46043332794950803,
        0.3358182962571003,
        0.23393257038094603,
        0.17416823348910626,
        0.15280466461838213,
        0.14065446928789968,
        0.13628644037225612,
        0.11865843081998025,
        0.09100784838995052,
        0.06354589377971084,
        0.04355413673755179,
        0.026543552858969845,
        0.008452123531952786,
        0.00005383070747585989,
        0.0000017910978540577104,
        0.000002429935453965725,
        0.00011234956972470801,
        0.000005256536961235961,
        0.0000061405395706453045,
        0.00002835226571901181,
        0.001086452313916946
      ],
      "range": 1
    }
  }
]
