[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad13,10 back camera / prf-solomatov-pred-ipad13-10-back-camera-146ecea0786b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad13,10 back camera / prf-solomatov-pred-ipad13-10-back-camera-146ecea0786b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27030686 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27030686; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011955784252016394,
        0.019837833564416384,
        0.013959114097215291,
        0.00009582264393881827,
        0.000046103180659196,
        0.0000028372272904949584,
        0.0050615422782832814,
        0.04568552570215939,
        0.09721657082620842,
        0.11036615200960864,
        0.10131026641351241,
        0.08803889771794915,
        0.06774926096955143,
        0.0298348772946421,
        0.000021184049860961723,
        0.000022926869114605527,
        0.020371308001580133,
        0.24974142350660283,
        0.5854308322030748,
        0.7490379637423926,
        0.7319150538761762,
        0.6646137282642401,
        0.571582312043431,
        0.49794000788585246,
        0.4284663733654411,
        0.35206137202733223,
        0.2800440358783347,
        0.1957380067971638,
        0.11339658564344242,
        0.04288004381390839,
        0.030723245425587794
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad13,10 back camera / prf-solomatov-pred-ipad13-10-back-camera-146ecea0786b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad13,10 back camera / prf-solomatov-pred-ipad13-10-back-camera-146ecea0786b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27030686 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27030686; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.017155694827722834,
        0.02846985089464618,
        0.054831841855585914,
        0.08738024258799795,
        0.12164602481786811,
        0.15154559525422331,
        0.20415787079913547,
        0.30146541600904986,
        0.4212272489125877,
        0.5410763899961696,
        0.6810483463127796,
        0.8477758204138808,
        0.9607950756410696,
        1,
        0.9807946790547603,
        0.9219838149871595,
        0.8316958733492742,
        0.6969060274681893,
        0.5448598307863886,
        0.40251971407606896,
        0.2941149551291447,
        0.20916135831698834,
        0.15782929075495902,
        0.10916688906822418,
        0.06990622805503345,
        0.03772085547514407,
        0.021428557159074692,
        0.005491215798222805,
        0.0015338687297836245,
        0.005493362987532022,
        0.002792895822177802
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad13,10 back camera / prf-solomatov-pred-ipad13-10-back-camera-146ecea0786b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad13,10 back camera / prf-solomatov-pred-ipad13-10-back-camera-146ecea0786b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27030686 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27030686; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04619241627829941,
        0.11016097778650531,
        0.26340859421769763,
        0.45366671419289917,
        0.57871938581211,
        0.6565024653832315,
        0.712064540278408,
        0.7168772187283742,
        0.6696205194348379,
        0.5805246304144853,
        0.45198841790400734,
        0.32958153559254844,
        0.22375091405375358,
        0.1479035863166773,
        0.1129004791073375,
        0.08635968395326706,
        0.07556232942071837,
        0.08190091808990715,
        0.09581404630278345,
        0.08127013498658525,
        0.05254534050671152,
        0.02798225468639605,
        0.009344748409270857,
        0.008596887626159396,
        0.011314858971762686,
        0.014838339655900708,
        0.016523387530749313,
        0.014536709871144225,
        0.008726878037797488,
        0.0011047771780560807,
        0.0016942756465744156
      ],
      "range": 1
    }
  }
]
