    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad13,18 back camera / prf-solomatov-pred-ipad13-18-back-camera-8ab7de017388@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad13,18 back camera / prf-solomatov-pred-ipad13-18-back-camera-8ab7de017388@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000502273886792 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26620516; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011904783241241453,
        0.028480093616700668,
        0.019237156624397726,
        0.00005475121549633128,
        0.0001536053829514595,
        0.00007227455612722825,
        0.0106295033385398,
        0.06960067190282863,
        0.13432107566021634,
        0.14473211762917082,
        0.12200769662015568,
        0.08870231567733286,
        0.05189379492406995,
        0.000024560062622377412,
        0.0002297500746055049,
        0.0007497627578259222,
        0.0010584193342243467,
        0.1763702588727286,
        0.5356431541436844,
        0.6957412483626652,
        0.6623101633341743,
        0.5904447255002525,
        0.504916688704403,
        0.4490361708777009,
        0.40058071834050846,
        0.34542367594631496,
        0.2857441367265895,
        0.2097229439532512,
        0.12513345666530723,
        0.05202571765608759,
        0.03941942651621457
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad13,18 back camera / prf-solomatov-pred-ipad13-18-back-camera-8ab7de017388@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad13,18 back camera / prf-solomatov-pred-ipad13-18-back-camera-8ab7de017388@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000502273886792 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26620516; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.021873147378134967,
        0.03460300604607217,
        0.06780554999653007,
        0.11669208292074863,
        0.16055026284648619,
        0.18831120328396336,
        0.23571979106510244,
        0.33283540377238974,
        0.4519091113473032,
        0.5784448738862975,
        0.7211486591770047,
        0.8800973596130613,
        0.9771190530121724,
        1,
        0.9666795381092955,
        0.8993730187785854,
        0.804239074210926,
        0.6685768672922213,
        0.5189364085022711,
        0.39230988043779996,
        0.301240572747225,
        0.2295659662903801,
        0.17725095440456284,
        0.12205939041735911,
        0.07641258349622147,
        0.038655106864541273,
        0.01880170923490557,
        0.0027822998644993014,
        0.000009058879326712657,
        0.0030425331033936487,
        0.00019315352436122146
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad13,18 back camera / prf-solomatov-pred-ipad13-18-back-camera-8ab7de017388@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad13,18 back camera / prf-solomatov-pred-ipad13-18-back-camera-8ab7de017388@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000502273886792 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26620516; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06147775807576382,
        0.15080077757302382,
        0.3469449348944321,
        0.5711702146272936,
        0.7072937970439449,
        0.7826460806060676,
        0.8265820658283127,
        0.7990740347655009,
        0.7147211931704605,
        0.5834563278264058,
        0.43112613594717697,
        0.301689357657418,
        0.20339400243608524,
        0.13491269290197078,
        0.10377038319979583,
        0.07800066337078992,
        0.062360434577172406,
        0.07179053745153524,
        0.09143308990549322,
        0.07604955739107513,
        0.039837312256957504,
        0.011896557478019007,
        0.001765344612403456,
        0.005620184799012887,
        0.01437617540922197,
        0.020908443594059908,
        0.024438577066582097,
        0.021001726812014673,
        0.012873160193880715,
        0.004945905691467547,
        0.005158365493097772
      ],
      "range": 1
    }
  }
]