[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad13,4 back camera / prf-solomatov-pred-ipad13-4-back-camera-120119840fe2@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad13,4 back camera / prf-solomatov-pred-ipad13-4-back-camera-120119840fe2@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2702798 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2702798; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011417217638906052,
        0.020206704311605973,
        0.01600681589967138,
        0.00004398256177487182,
        0.000022724282761789817,
        0.0000016490163156847088,
        0.005121633211212972,
        0.04539130930243399,
        0.09789433024591553,
        0.11056291665155886,
        0.09946876163146487,
        0.08591284661302842,
        0.06646998406836174,
        0.026213900187879374,
        0.000057738358545477686,
        0.00015722091329059735,
        0.00009350370985919037,
        0.25053439435725494,
        0.6107631424915957,
        0.762409436443271,
        0.7269709390046907,
        0.6601855928559959,
        0.5667682897501034,
        0.491447381565326,
        0.4235332644170966,
        0.3479591889589973,
        0.27319352019647786,
        0.18992916229773738,
        0.10970348505511696,
        0.04217499050983462,
        0.03501835875267038
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad13,4 back camera / prf-solomatov-pred-ipad13-4-back-camera-120119840fe2@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad13,4 back camera / prf-solomatov-pred-ipad13-4-back-camera-120119840fe2@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2702798 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2702798; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01734628337004837,
        0.028180774145903614,
        0.05372027062325782,
        0.0862586179211321,
        0.12053434995882045,
        0.1495944203007402,
        0.20073099432514008,
        0.29930930835378744,
        0.42326966351166456,
        0.5466981254240976,
        0.6881896834317622,
        0.8523143053975917,
        0.9617668061024167,
        1,
        0.9800646589201265,
        0.9201847492857401,
        0.8310223701512285,
        0.69681515229773,
        0.5424222231924102,
        0.40189425920842026,
        0.2953027936234968,
        0.2110092948122649,
        0.15837987152573,
        0.1104550506549139,
        0.06972202140152538,
        0.037613743239413376,
        0.02147253179852878,
        0.006299593976316394,
        0.0011225682422437784,
        0.005748170229517706,
        0.00007467037862244977
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad13,4 back camera / prf-solomatov-pred-ipad13-4-back-camera-120119840fe2@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad13,4 back camera / prf-solomatov-pred-ipad13-4-back-camera-120119840fe2@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2702798 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2702798; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04483011309021243,
        0.11231146019791342,
        0.268474018406111,
        0.4567945514241168,
        0.5785741294761947,
        0.6561572488954039,
        0.7112532272112085,
        0.7130410781715836,
        0.6656360926713724,
        0.5748156909987353,
        0.4471411478031284,
        0.3242673333338266,
        0.219498737974499,
        0.14467164767770288,
        0.11083081680539944,
        0.0838868942481088,
        0.07327033688792133,
        0.08335944824585484,
        0.09962068937449264,
        0.08272547559973036,
        0.051535838046350486,
        0.02605210748269016,
        0.008161423828195818,
        0.006786424660666464,
        0.01042942535846186,
        0.01518428014228218,
        0.01541908052322075,
        0.01379235629151716,
        0.008659938330574463,
        0.0010213561279829272,
        0.003230576461873954
      ],
      "range": 1
    }
  }
]
