[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad14,3 back camera / prf-solomatov-pred-ipad14-3-back-camera-8883bd8a0c2a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad14,3 back camera / prf-solomatov-pred-ipad14-3-back-camera-8883bd8a0c2a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27022058 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27022058; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.012035973351844632,
        0.021876020693908656,
        0.02096123100616541,
        0.000014159097726753455,
        0.00003190332135324408,
        0.006239370443213467,
        0.03630880001811854,
        0.06594421120700726,
        0.10854239895421734,
        0.11679795077044094,
        0.10615449052770148,
        0.09512320638198615,
        0.08104672856523364,
        0.04984283950541443,
        0.00939179169847093,
        0.00024944957930295316,
        0.040942444132123466,
        0.26298622406924005,
        0.5928810455517489,
        0.7424488541916385,
        0.7133389692228476,
        0.641500399414434,
        0.5488810289727007,
        0.47586690103322254,
        0.409507151527837,
        0.3350441332040661,
        0.2659508391255766,
        0.18386475227016388,
        0.1094556898664047,
        0.0417421648639789,
        0.03326887241526904
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad14,3 back camera / prf-solomatov-pred-ipad14-3-back-camera-8883bd8a0c2a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad14,3 back camera / prf-solomatov-pred-ipad14-3-back-camera-8883bd8a0c2a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27022058 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27022058; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.018945444495752323,
        0.028944016773259834,
        0.05575660077407872,
        0.08832466054213932,
        0.12558919087509915,
        0.16128998760938196,
        0.21797679880636775,
        0.32449782322279086,
        0.45487116488314844,
        0.5799022783534844,
        0.7156302454831531,
        0.8717115476548826,
        0.97113972592317,
        1,
        0.9730429488383158,
        0.9093622698907686,
        0.8164765614817348,
        0.6804566476765019,
        0.5285314686246325,
        0.3885791378288064,
        0.27442125244494703,
        0.18584941605854002,
        0.13380674410513071,
        0.09031038642578594,
        0.05886088690950186,
        0.03482174821769682,
        0.022253876074131734,
        0.009506905062523366,
        0.006029215465380172,
        0.007020075969047214,
        0.0027358832180731756
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad14,3 back camera / prf-solomatov-pred-ipad14-3-back-camera-8883bd8a0c2a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad14,3 back camera / prf-solomatov-pred-ipad14-3-back-camera-8883bd8a0c2a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27022058 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27022058; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04647708919875755,
        0.11105499070426095,
        0.26101981203652214,
        0.44515032866852705,
        0.5693441261949774,
        0.6462923364312223,
        0.7046815975304325,
        0.7120298535366922,
        0.6763308331289942,
        0.594383003692761,
        0.47847088478605143,
        0.3695969418761517,
        0.2670795466429685,
        0.18947327401932157,
        0.14609000173117828,
        0.10856028434251752,
        0.08498788656289613,
        0.08085611391996865,
        0.08858211317583584,
        0.06866451844637445,
        0.032408915708788726,
        0.006343359191960879,
        0.000359753946202025,
        0.004868733906203591,
        0.01537935785645934,
        0.02235421669215572,
        0.025602304976179092,
        0.021355272052187884,
        0.014437865909398908,
        0.005963917700124838,
        0.005859840505116228
      ],
      "range": 1
    }
  }
]
