[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad6,3 back camera / prf-solomatov-pred-ipad6-3-back-camera-70dec814ba8a@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad6,3 back camera / prf-solomatov-pred-ipad6-3-back-camera-70dec814ba8a@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000506369339623 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26837575; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01787440074224292,
        0.03157071180438838,
        0.02699891519366304,
        0.0007258900037952255,
        0.0005672281264743046,
        0.00021571707163888277,
        0.02934617415256813,
        0.06696464818766622,
        0.11741121946872372,
        0.11433531501399566,
        0.08908585190726061,
        0.057173585987585845,
        0.02576421485404469,
        0.000006940876737186575,
        0.0007040703331195299,
        0.0007201327866890832,
        0.0009763217362756722,
        0.19573140185702256,
        0.5303934193910512,
        0.6831481039019461,
        0.6561996827209612,
        0.5874581654180935,
        0.49788718771854323,
        0.42943643587602665,
        0.3672334002559844,
        0.3012083268156106,
        0.23752521220600956,
        0.16342420048433706,
        0.09244301572131829,
        0.03540385097375979,
        0.02494167316852265
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad6,3 back camera / prf-solomatov-pred-ipad6-3-back-camera-70dec814ba8a@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad6,3 back camera / prf-solomatov-pred-ipad6-3-back-camera-70dec814ba8a@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000506369339623 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26837575; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.02361841162996284,
        0.03728690288459098,
        0.07165321364684012,
        0.11549544751654055,
        0.15950180763351382,
        0.18666343438257743,
        0.2274096964715556,
        0.31144292633060255,
        0.42050233891599126,
        0.5384613664283173,
        0.681383040010135,
        0.8498325304916633,
        0.9632504993178692,
        1,
        0.9749005362540863,
        0.9106173198652194,
        0.8148530624906097,
        0.6731045545252238,
        0.5134156251012838,
        0.37444260424335174,
        0.27605956573945295,
        0.20075591349985614,
        0.15652411212216813,
        0.10771058245466049,
        0.06885311167039124,
        0.03449844916774623,
        0.019779724255332986,
        0.0037222632819843074,
        0.0010505122728772887,
        0.004619412753644248,
        0.00004449809588661739
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad6,3 back camera / prf-solomatov-pred-ipad6-3-back-camera-70dec814ba8a@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad6,3 back camera / prf-solomatov-pred-ipad6-3-back-camera-70dec814ba8a@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000506369339623 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26837575; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.062840129743466,
        0.15300043025315138,
        0.3486641459471158,
        0.572038657445504,
        0.7090263049609973,
        0.7951933974826131,
        0.8528638153296507,
        0.842284577151188,
        0.7687348746735376,
        0.6344686058974541,
        0.4660232789288898,
        0.3105652752406529,
        0.18725073449330762,
        0.10821429655995372,
        0.07891934584115602,
        0.06133289627085769,
        0.062005743014092306,
        0.07475569365293694,
        0.08534300830857097,
        0.07234349032867639,
        0.04487078874798983,
        0.021286211290223244,
        0.00017034875603064108,
        0.00016003105069652623,
        0.000003835593356516004,
        0.00008025997545490717,
        0.001686204526845121,
        0.0020193321957640118,
        0.0015485618961255541,
        0.0001326206460990564,
        0.0023767938427479273
      ],
      "range": 1
    }
  }
]
