    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone13,3 back telephoto camera / prf-solomatov-pred-iphone13-3-back-telephoto-camera-96aa61e38378@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone13,3 back telephoto camera / prf-solomatov-pred-iphone13-3-back-telephoto-camera-96aa61e38378@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000505381886792 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2678524; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.021223178511747515,
        0.03283288402629902,
        0.028538279940032364,
        0.00003117695781984476,
        0.000029018541894375752,
        0.000016738506066110375,
        0.034849888043466906,
        0.07557391817919919,
        0.12630452419877516,
        0.12760065785850563,
        0.10494412519731017,
        0.07468794256339188,
        0.04024129793412055,
        0.0034983922861994148,
        0.004662073313234923,
        0.00015657416927450276,
        0.006489730651497403,
        0.22419058262698072,
        0.5589999476809128,
        0.7001961287609223,
        0.6635356854496482,
        0.5898563298538948,
        0.49850845814890543,
        0.429453899900758,
        0.36854895994025066,
        0.3019723457339249,
        0.2390463830984618,
        0.16500251742566976,
        0.09331121625413188,
        0.03909710099044599,
        0.028520325106556554
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone13,3 back telephoto camera / prf-solomatov-pred-iphone13-3-back-telephoto-camera-96aa61e38378@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone13,3 back telephoto camera / prf-solomatov-pred-iphone13-3-back-telephoto-camera-96aa61e38378@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000505381886792 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2678524; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.025518761825542725,
        0.0391561708667289,
        0.07414449685189092,
        0.1182985081544216,
        0.16490590832182883,
        0.19930758714708385,
        0.24860902870386828,
        0.3456504331680672,
        0.4649270636863188,
        0.58454329202751,
        0.7198283308269778,
        0.8783303218708601,
        0.9769281055249371,
        1,
        0.9654746274855521,
        0.8967242630642848,
        0.7993347135533281,
        0.6610629939238335,
        0.5116586565508879,
        0.3787275505313083,
        0.27986036308305123,
        0.20078956624288136,
        0.1515638685769211,
        0.10589666026204957,
        0.06978376027944869,
        0.037657831931087654,
        0.023573877333979917,
        0.008895479727005811,
        0.0027651073051470757,
        0.0057498648292974,
        0.000003871714315154808
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone13,3 back telephoto camera / prf-solomatov-pred-iphone13-3-back-telephoto-camera-96aa61e38378@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone13,3 back telephoto camera / prf-solomatov-pred-iphone13-3-back-telephoto-camera-96aa61e38378@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000505381886792 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2678524; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06047047450386856,
        0.1477979461276653,
        0.3406766055804295,
        0.5607431251706728,
        0.6908866345114629,
        0.7698622657685934,
        0.8200003110084054,
        0.8035361107262092,
        0.727840275402921,
        0.6042921079989256,
        0.4540945886615166,
        0.32026550326326936,
        0.21411041398173025,
        0.144235855269544,
        0.113955501377016,
        0.09248129770520835,
        0.08449674615571862,
        0.08927716015998023,
        0.09261650040766148,
        0.07367255445694618,
        0.045273979469040916,
        0.023403758391182458,
        0.008307591227060488,
        0.0037359826021689793,
        0.0030401836515185233,
        0.0036295550603472433,
        0.003296110503736047,
        0.003476911431974443,
        0.0018313015203632343,
        0.00008772830370626575,
        0.0011740762801773345
      ],
      "range": 1
    }
  }
]