    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone14,2 back ultra wide camera / prf-solomatov-pred-iphone14-2-back-ultra-wide-camera-bee6d963933a@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone14,2 back ultra wide camera / prf-solomatov-pred-iphone14-2-back-ultra-wide-camera-bee6d963933a@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000504356 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26730868; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01860015296734846,
        0.032188790767032724,
        0.0288035274781343,
        0.0001176679881154452,
        0.00002592188490236694,
        0.000026282555267399304,
        0.03597094288471876,
        0.07788291806041088,
        0.1283290432088974,
        0.1297285477491522,
        0.10851155136451235,
        0.08178143776128252,
        0.050392949699144124,
        0.0036787993566089958,
        0.00013709453243343985,
        0.00007602707755488727,
        0.00014217460342637794,
        0.24468291890175595,
        0.5677322613665607,
        0.6942073200648827,
        0.6610093531817471,
        0.5856562545139531,
        0.495343726742938,
        0.42396838740889364,
        0.36097837514573033,
        0.2918763120311233,
        0.22701509299467884,
        0.1504039494491157,
        0.08457014256503226,
        0.032302878769436036,
        0.02431980301895599
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone14,2 back ultra wide camera / prf-solomatov-pred-iphone14-2-back-ultra-wide-camera-bee6d963933a@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone14,2 back ultra wide camera / prf-solomatov-pred-iphone14-2-back-ultra-wide-camera-bee6d963933a@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000504356 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26730868; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.023247693593414172,
        0.038614154461937354,
        0.07414282957351741,
        0.11867383448420614,
        0.1635840827438627,
        0.19956094504675267,
        0.25212158630532533,
        0.3495228716359248,
        0.47003276620746715,
        0.5875125700812885,
        0.7219774920889213,
        0.8790772048812703,
        0.9787744554060409,
        1,
        0.9672014447173262,
        0.8944192738318315,
        0.7955149381445984,
        0.6528006602966187,
        0.5014943262572331,
        0.36982009344757955,
        0.267387767767212,
        0.18787386583169394,
        0.14046944951070145,
        0.09725565162022742,
        0.06346482878661104,
        0.03631642362507068,
        0.021909400154340234,
        0.008711077747381231,
        0.003613759573653157,
        0.005644805066952363,
        0.0008637280582989565
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone14,2 back ultra wide camera / prf-solomatov-pred-iphone14-2-back-ultra-wide-camera-bee6d963933a@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone14,2 back ultra wide camera / prf-solomatov-pred-iphone14-2-back-ultra-wide-camera-bee6d963933a@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000504356 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26730868; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0625244172766855,
        0.14764987913105898,
        0.3411638755542664,
        0.5653917950535862,
        0.6993319653722226,
        0.7780292315568984,
        0.8310671775319503,
        0.8188090884132331,
        0.7481748589620559,
        0.6280709398495813,
        0.47711582691590854,
        0.34179399269641314,
        0.2287964941735294,
        0.15363969475289763,
        0.11832306941921973,
        0.09329547887891597,
        0.08298933972942014,
        0.08913743466916225,
        0.09436328635958015,
        0.07310121005461435,
        0.045231288349234795,
        0.021891721941397362,
        0.007570097695969487,
        0.004417552378913004,
        0.004389628494059751,
        0.004490632990006448,
        0.0058266055818677375,
        0.004002484977739603,
        0.001906402888622555,
        0.000019457937520782707,
        0.0013232852531601825
      ],
      "range": 1
    }
  }
]