[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone9,2 back telephoto camera / prf-solomatov-pred-iphone9-2-back-telephoto-camera-3d5fe1fc8d29@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone9,2 back telephoto camera / prf-solomatov-pred-iphone9-2-back-telephoto-camera-3d5fe1fc8d29@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000516605283019 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2738008; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.017153899294669702,
        0.02829275713067809,
        0.025454632484986302,
        0.0006350188955909076,
        0.000003166551135317753,
        0.00006520485217314518,
        0.025063911991301074,
        0.054493969120709404,
        0.09486552069363323,
        0.09237153396907234,
        0.07565073622867427,
        0.0590327858077557,
        0.04667804568138589,
        0.024097280577704668,
        0.00003821314214161861,
        0.000023789611711075418,
        0.049742581428855265,
        0.2422383008428153,
        0.5141418512013617,
        0.6371183622843162,
        0.6096170719734931,
        0.5442676136548428,
        0.4594205137221965,
        0.39029669258331845,
        0.32475826603455865,
        0.25643902259767515,
        0.19734021960490986,
        0.13475410699496662,
        0.07716988274816194,
        0.031039130865646997,
        0.018154027057001188
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone9,2 back telephoto camera / prf-solomatov-pred-iphone9-2-back-telephoto-camera-3d5fe1fc8d29@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone9,2 back telephoto camera / prf-solomatov-pred-iphone9-2-back-telephoto-camera-3d5fe1fc8d29@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000516605283019 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2738008; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.021172925170415864,
        0.03520499770849963,
        0.06760465172559932,
        0.10495233404451636,
        0.1435123816624747,
        0.17280284417641503,
        0.22080696273888994,
        0.31752085069207325,
        0.4393023131841348,
        0.5610568220936311,
        0.7038920273425059,
        0.8669967434747609,
        0.9733386419840769,
        1,
        0.9646827831685583,
        0.8896214235113464,
        0.7835971867399323,
        0.642586021175492,
        0.49368476002034806,
        0.35680275153892654,
        0.24447952976519186,
        0.15987742291140844,
        0.11348823034141797,
        0.0809104145718173,
        0.05617180566355175,
        0.035267774179678746,
        0.02701867921806103,
        0.013556337117207816,
        0.006955419521826688,
        0.007202706503774097,
        0.00202851542591757
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone9,2 back telephoto camera / prf-solomatov-pred-iphone9-2-back-telephoto-camera-3d5fe1fc8d29@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone9,2 back telephoto camera / prf-solomatov-pred-iphone9-2-back-telephoto-camera-3d5fe1fc8d29@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000516605283019 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2738008; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06379569873426229,
        0.15355562822920363,
        0.3511565585880927,
        0.572834448374724,
        0.7081737401457887,
        0.7904257361150474,
        0.846748481885847,
        0.8373110639155772,
        0.7703186160644283,
        0.6453487852244018,
        0.48539128081437316,
        0.3363702857454519,
        0.21271265389908395,
        0.13518377594221784,
        0.1064779765002445,
        0.09211406872840001,
        0.09288178962067103,
        0.09397311713158912,
        0.08614907827779954,
        0.0673731897577994,
        0.049954199427710455,
        0.034726535064788754,
        0.019576306864863658,
        0.0020978144271773433,
        0.000013056152473577506,
        0.000003842344041024322,
        0.00013434908771986677,
        0.00003014257489168397,
        0.000014057550496780226,
        0.000013861295066562514,
        0.0009501226600819697
      ],
      "range": 1
    }
  }
]
