    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Konica Minolta Maxxum 5D / prf-solomatov-pred-konica-minolta-maxxum-5d-8a8f2873f0e8@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Konica Minolta Maxxum 5D / prf-solomatov-pred-konica-minolta-maxxum-5d-8a8f2873f0e8@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000530719471698 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28128132; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.012142573136388864,
        0.021409978885022364,
        0.02713507131782313,
        0.007409443700886936,
        0.02217744571358473,
        0.03813264188480218,
        0.051809594966596303,
        0.054749611905913195,
        0.06257921184563554,
        0.05423434986869431,
        0.03601489679442631,
        0.022459944727221844,
        0.02230333004475596,
        0.00847266359529314,
        0.000006754515971833887,
        0.0000027239564484927242,
        0.039705338794424234,
        0.21987968748455144,
        0.47469808566715704,
        0.6025072999659835,
        0.579483888822289,
        0.522116160969451,
        0.4423298807824689,
        0.385145421458071,
        0.3320663210944829,
        0.27960180658555367,
        0.2258919808306309,
        0.15752870715540998,
        0.09484516614687304,
        0.03852637992455382,
        0.02626516999320924
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Konica Minolta Maxxum 5D / prf-solomatov-pred-konica-minolta-maxxum-5d-8a8f2873f0e8@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Konica Minolta Maxxum 5D / prf-solomatov-pred-konica-minolta-maxxum-5d-8a8f2873f0e8@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000530719471698 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28128132; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01927046640530555,
        0.030114740228490214,
        0.06145993330330883,
        0.10860050002609488,
        0.14931170994091025,
        0.1649054500550078,
        0.20328249482852567,
        0.2927821967201997,
        0.4056163201962126,
        0.5379708246301936,
        0.6921746790721829,
        0.8656344885207004,
        0.9720742106706007,
        1,
        0.9637608829954772,
        0.8886541035598357,
        0.7779763143988984,
        0.617454394742539,
        0.4412982078361731,
        0.2981754014396497,
        0.19584951286491403,
        0.12336990626312196,
        0.08481142106323283,
        0.05022354691533931,
        0.021665106262655477,
        0.0012648936549468587,
        0.000026179170344156134,
        0.00001891623346834047,
        0.00004181991119612711,
        0.00009711152418562642,
        0.00014478544926379856
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Konica Minolta Maxxum 5D / prf-solomatov-pred-konica-minolta-maxxum-5d-8a8f2873f0e8@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Konica Minolta Maxxum 5D / prf-solomatov-pred-konica-minolta-maxxum-5d-8a8f2873f0e8@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000530719471698 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28128132; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06131586550966129,
        0.15145809653151932,
        0.34666677846797306,
        0.5620795430494762,
        0.7110268951964661,
        0.8086172337675637,
        0.8658126876401673,
        0.8434558168737081,
        0.7538487854733238,
        0.592407247125332,
        0.41157479920813794,
        0.2519589107445883,
        0.13767488151664728,
        0.06578469910479658,
        0.04326251529041248,
        0.028108631729841273,
        0.02689341149890183,
        0.030347310831458012,
        0.03188158431811133,
        0.0214260013210202,
        0.0031980156319421898,
        0.00004239726811927506,
        0.000004637205630888471,
        0.00002930381115439761,
        0.00009531161743161614,
        0.0018648261298852527,
        0.004333457267276157,
        0.005099822727853796,
        0.0032266847234480203,
        0.0014903645888769996,
        0.0012327081427640789
      ],
      "range": 1
    }
  }
]