[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica D LUX 6 / prf-solomatov-pred-leica-d-lux-6-b8716d1d0ae6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica D LUX 6 / prf-solomatov-pred-leica-d-lux-6-b8716d1d0ae6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2641554 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2641554; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011507675027654176,
        0.02013697353906072,
        0.021570863211579243,
        0.00014068094008299662,
        0.000004941444695054503,
        0.006672494296917649,
        0.03622968525345308,
        0.06818316036696581,
        0.10932655929047827,
        0.11707703495745309,
        0.10678639164673523,
        0.08987343056397865,
        0.06803294575844371,
        0.028611111489676155,
        0.0000056323974448373955,
        0.000008392272124666012,
        0.00990074024608242,
        0.2479096016965771,
        0.6002979306877694,
        0.7702328250719085,
        0.7490802005183312,
        0.6791830869253478,
        0.5888143115756862,
        0.5155162075051277,
        0.4503714480188556,
        0.37646040928938046,
        0.30120372326289757,
        0.21843455783981702,
        0.12520804041863237,
        0.05386119874891825,
        0.037062145994365435
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica D LUX 6 / prf-solomatov-pred-leica-d-lux-6-b8716d1d0ae6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica D LUX 6 / prf-solomatov-pred-leica-d-lux-6-b8716d1d0ae6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2641554 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2641554; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01707282796414535,
        0.03084269713963826,
        0.05966880101637143,
        0.09757171346866277,
        0.13858995500375915,
        0.17623248284911078,
        0.23566396901217998,
        0.3433211662528951,
        0.46855320769516734,
        0.5878450336430753,
        0.7218902206807054,
        0.8741129653226851,
        0.9736916224313416,
        1,
        0.9761397268426086,
        0.9141276309323982,
        0.8255297449910167,
        0.6981434791793013,
        0.5605400457457997,
        0.42520546617634924,
        0.3120763383977765,
        0.22657282796414535,
        0.16974258334298675,
        0.11975405386374838,
        0.08124345744966789,
        0.05085467872320611,
        0.035754120491195716,
        0.017466256605013563,
        0.00801211218850722,
        0.007317387416649442,
        0.0015293970140303776
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica D LUX 6 / prf-solomatov-pred-leica-d-lux-6-b8716d1d0ae6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica D LUX 6 / prf-solomatov-pred-leica-d-lux-6-b8716d1d0ae6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2641554 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2641554; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.047462826805736325,
        0.11410339519843245,
        0.2686707142840919,
        0.4588674923927355,
        0.5836253962629574,
        0.6599332816970618,
        0.7149411293503749,
        0.7197193394494302,
        0.6765278317232962,
        0.5880521087208516,
        0.4712320474993129,
        0.36337008442757557,
        0.2650515757012728,
        0.1935257276587948,
        0.15150697657515236,
        0.11645058931220033,
        0.09155879455805181,
        0.07955315696745174,
        0.07490650579166658,
        0.05175685221653618,
        0.021567154788431356,
        0.005326539605096091,
        0.0024062993601493667,
        0.0013929002397830975,
        0.006073833054330898,
        0.0099093817502879,
        0.012777228858467403,
        0.00974401053319372,
        0.005330537251935792,
        0.002735780907753542,
        0.002156509388034468
      ],
      "range": 1
    }
  }
]
