    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica D LUX (Typ 109) / prf-solomatov-pred-leica-d-lux-typ-109-bef86f776c5a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica D LUX (Typ 109) / prf-solomatov-pred-leica-d-lux-typ-109-bef86f776c5a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27225417 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27225417; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01226546539213706,
        0.024738037988545774,
        0.02613149322928644,
        0.00013602373840591677,
        0.004739758439696258,
        0.022734445169379773,
        0.04459744363144189,
        0.06137626468678147,
        0.09052079532886494,
        0.08307859894303914,
        0.06784699753175498,
        0.052233014465857396,
        0.04072898130449205,
        0.01453912533277268,
        0.0000591659624533942,
        0.00007180941617900654,
        0.03543819732862127,
        0.2606489002537592,
        0.5739672968094482,
        0.7149016670708844,
        0.6866058653940911,
        0.6226317855847717,
        0.5333654944568892,
        0.45225099766148663,
        0.37781560517512,
        0.299860163758006,
        0.2306834639116822,
        0.15619641014130287,
        0.08864418862712001,
        0.036693693249950955,
        0.024449219639133532
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica D LUX (Typ 109) / prf-solomatov-pred-leica-d-lux-typ-109-bef86f776c5a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica D LUX (Typ 109) / prf-solomatov-pred-leica-d-lux-typ-109-bef86f776c5a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27225417 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27225417; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.017850917398253258,
        0.029038853656493124,
        0.056952989921146106,
        0.08986965378712106,
        0.12752356740761767,
        0.15834983537625888,
        0.20665520017563,
        0.2967991270804043,
        0.40874117740786114,
        0.5218878741141044,
        0.6632759747995779,
        0.8336967253798169,
        0.9544271810418918,
        1,
        0.9866964755764807,
        0.9294014853840439,
        0.8362139320033188,
        0.6939634019196106,
        0.5342464726986551,
        0.38536243540365234,
        0.2659505270387594,
        0.17418673513797786,
        0.12493413783157112,
        0.08446984668774771,
        0.05574334821024045,
        0.03189615057135764,
        0.022709613593797296,
        0.009939621861439256,
        0.004213277982115021,
        0.006798414510969656,
        0.000042367707352287755
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica D LUX (Typ 109) / prf-solomatov-pred-leica-d-lux-typ-109-bef86f776c5a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica D LUX (Typ 109) / prf-solomatov-pred-leica-d-lux-typ-109-bef86f776c5a@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27225417 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27225417; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04555115905111756,
        0.11065322525638449,
        0.2638828635756066,
        0.4476801585812258,
        0.5761889340391003,
        0.6653097728493929,
        0.7375820910291291,
        0.7590937541930027,
        0.7310602441828531,
        0.6430521890628893,
        0.5063104451255972,
        0.3639951961066381,
        0.23310166378718827,
        0.14307608952325687,
        0.10381540896141278,
        0.08066741824376832,
        0.07859354367281132,
        0.07891254705116178,
        0.07101305739412549,
        0.05447107201333224,
        0.03732028971310154,
        0.024145398397387264,
        0.005183195541137166,
        0.00003674298909728362,
        0.00003579306792619558,
        0.000027005551466851727,
        0.000012778660102800261,
        0.00002943511204989073,
        0.00013481863657037831,
        0.000017048754110910402,
        0.0001554596427301738
      ],
      "range": 1
    }
  }
]