[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica DIGILUX 3 / prf-solomatov-pred-leica-digilux-3-b3dc37de45e4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica DIGILUX 3 / prf-solomatov-pred-leica-digilux-3-b3dc37de45e4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28488404 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28488404; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.008299149717197214,
        0.01655507272362467,
        0.021522600915095138,
        0.00536349667043475,
        0.024004010193059602,
        0.027860528796207745,
        0.026295188737143715,
        0.012245284081200196,
        0.005170249621565322,
        0.00005239420572665285,
        0.0001393399047556332,
        0.0169140563297263,
        0.04705309570869607,
        0.07024631846698046,
        0.07948333644805093,
        0.09929139940587757,
        0.15022222726130954,
        0.28891586906728783,
        0.4871164421846868,
        0.5944246297546187,
        0.5737327019091698,
        0.5125508259430749,
        0.43248029970369695,
        0.36068033154823276,
        0.29127122740887834,
        0.2233064723457306,
        0.16624497462195495,
        0.10668093235409046,
        0.06023733726887613,
        0.021695485643913222,
        0.012279658769231157
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica DIGILUX 3 / prf-solomatov-pred-leica-digilux-3-b3dc37de45e4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica DIGILUX 3 / prf-solomatov-pred-leica-digilux-3-b3dc37de45e4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28488404 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28488404; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015039837261504716,
        0.02187210838487126,
        0.042308474002264215,
        0.06793660676814327,
        0.08775745738511712,
        0.10108352507216621,
        0.1435007310342833,
        0.2419555339077612,
        0.36255144373830134,
        0.48949495380646807,
        0.6483138893986479,
        0.8301030482437696,
        0.9571833859137915,
        1,
        0.9753780520663775,
        0.9030223665741332,
        0.7934152787218266,
        0.6427283536136317,
        0.4779936777083054,
        0.32233501041335977,
        0.1898981424161213,
        0.0931818820036391,
        0.05364831248531859,
        0.03461770620776088,
        0.02159134748299694,
        0.014243970985528006,
        0.01896426349471876,
        0.010856165547217035,
        0.0052174210952638835,
        0.007825356590702659,
        0.0007841880155869736
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica DIGILUX 3 / prf-solomatov-pred-leica-digilux-3-b3dc37de45e4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica DIGILUX 3 / prf-solomatov-pred-leica-digilux-3-b3dc37de45e4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28488404 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28488404; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04247118933022713,
        0.1093636519616894,
        0.2649646291171664,
        0.45349879902012064,
        0.5934670822556434,
        0.6909391624746687,
        0.7691008945253655,
        0.7925079621870007,
        0.7631711836156213,
        0.6591455246141553,
        0.5063914777395041,
        0.348116377456596,
        0.20860530832123833,
        0.11847743383588634,
        0.09024189631683123,
        0.07897164053135443,
        0.08098388031846221,
        0.0675971142504157,
        0.037629549201843665,
        0.018911109937924216,
        0.015060011785848024,
        0.012105819616992232,
        0.000038239776436756514,
        0.00002224638839016745,
        0.0000625880094932661,
        0.00001853919335038916,
        0.0001266185357382604,
        0.000018112239632658957,
        0.00007980834236975858,
        0.00011049797665042942,
        0.0010469182478597256
      ],
      "range": 1
    }
  }
]
