    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA M (Typ 240) / prf-solomatov-pred-leica-m-typ-240-2d0a5cfa5931@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA M (Typ 240) / prf-solomatov-pred-leica-m-typ-240-2d0a5cfa5931@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2827544 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2827544; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.010032375800341215,
        0.018647695668042655,
        0.017771436978522702,
        0.000041744142619884956,
        0.000025552990510492497,
        0.00009222268512886095,
        0.00557627538245205,
        0.013562153939956372,
        0.03239686455807584,
        0.03485667773870185,
        0.03721211058077257,
        0.04848581312969842,
        0.06901788265717526,
        0.08014532753513295,
        0.0800805257141887,
        0.09621137637469124,
        0.1463486686679323,
        0.3100039822545644,
        0.5262630749512651,
        0.6157573498414171,
        0.5794558457799418,
        0.5146776849449558,
        0.43332239569039416,
        0.36056835897160217,
        0.29182198402571274,
        0.2225131421473901,
        0.16512458868898236,
        0.1049516647663131,
        0.05726545723072744,
        0.023994206633035597,
        0.014246133747167152
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA M (Typ 240) / prf-solomatov-pred-leica-m-typ-240-2d0a5cfa5931@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA M (Typ 240) / prf-solomatov-pred-leica-m-typ-240-2d0a5cfa5931@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2827544 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2827544; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015761247216665768,
        0.024800678610129495,
        0.04631093981207719,
        0.07370923317196831,
        0.09885389228248968,
        0.11735547528172857,
        0.16189589622654854,
        0.2582991635143432,
        0.3724456630913613,
        0.49077174395871465,
        0.6440523648792025,
        0.8275576259821243,
        0.9564043212059653,
        1,
        0.9772545360920996,
        0.9050001697586314,
        0.7994487795769049,
        0.6614940032763416,
        0.5163643784146241,
        0.3653864625979295,
        0.2276590921308386,
        0.12414020789773739,
        0.0779786379982062,
        0.06036772902561374,
        0.050127690320645756,
        0.040651278989822966,
        0.04242736275721969,
        0.02656730717541442,
        0.015542239130496288,
        0.010964620179208528,
        0.004821469798524798
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA M (Typ 240) / prf-solomatov-pred-leica-m-typ-240-2d0a5cfa5931@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA M (Typ 240) / prf-solomatov-pred-leica-m-typ-240-2d0a5cfa5931@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2827544 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2827544; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.045537247165738176,
        0.11098873439281581,
        0.26507700675922286,
        0.44959972329343056,
        0.5840557034656225,
        0.6796425802746128,
        0.7549649802089728,
        0.777135811149181,
        0.7516281267417942,
        0.6569077970139456,
        0.50910712618442,
        0.35435628941583225,
        0.21643599533729624,
        0.1251920748182875,
        0.09797388829316184,
        0.08584061645017725,
        0.09372110212962202,
        0.08121522423700568,
        0.05450304752109958,
        0.04161616936818666,
        0.04889263969013391,
        0.05278035991659192,
        0.03685752723918708,
        0.007435033371717646,
        0.00007370902451031707,
        0.000028835855427890775,
        0.00008296701306858531,
        0.000043095233884954576,
        0.00013596903885492142,
        0.000005174419920609546,
        0.000051712815079093373
      ],
      "range": 1
    }
  }
]