[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA S (Typ 006) / prf-solomatov-pred-leica-s-typ-006-7d7861a742d7@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA S (Typ 006) / prf-solomatov-pred-leica-s-typ-006-7d7861a742d7@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27203265 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27203265; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.012991483559050726,
        0.025587942109154913,
        0.030848308098310993,
        0.004238919115040052,
        0.009131422275965771,
        0.03033264940807657,
        0.049089228811320995,
        0.0654943478292036,
        0.08953689933910507,
        0.05849300074825577,
        0.03059847779301492,
        0.010980547371795261,
        0.013969163260365989,
        0.023408040909795202,
        0.04677019100464595,
        0.08024563963186038,
        0.14222589089949314,
        0.2747163254116739,
        0.4560007410875129,
        0.5550453962051981,
        0.5139612101709116,
        0.4382072519603805,
        0.3689446101414665,
        0.31887606138454333,
        0.25286424258264584,
        0.18477824261168652,
        0.13812881284654618,
        0.08730107213233412,
        0.04776464148696857,
        0.02159345578554633,
        0.0051645513874897
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA S (Typ 006) / prf-solomatov-pred-leica-s-typ-006-7d7861a742d7@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA S (Typ 006) / prf-solomatov-pred-leica-s-typ-006-7d7861a742d7@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27203265 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27203265; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016859918836948432,
        0.02957298508101877,
        0.05849768400962164,
        0.09345415706533756,
        0.13377111166619157,
        0.1573272840594686,
        0.18893390186802947,
        0.25585450864078263,
        0.3478157860830309,
        0.45770716860641547,
        0.6056625188189727,
        0.7914199637433228,
        0.9383538336298971,
        1,
        0.9953314427514491,
        0.9356608480636424,
        0.8397648958681982,
        0.7179587450256432,
        0.5971108615087197,
        0.4427130713905114,
        0.28501453777699115,
        0.1554894421680633,
        0.09566753843702218,
        0.08244539028679095,
        0.08332189904410371,
        0.07602769373455724,
        0.09160373212553714,
        0.06472881104529181,
        0.03753574800671905,
        0.022717446968222383,
        0.0026004510855590314
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA S (Typ 006) / prf-solomatov-pred-leica-s-typ-006-7d7861a742d7@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA S (Typ 006) / prf-solomatov-pred-leica-s-typ-006-7d7861a742d7@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27203265 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27203265; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0493214215278938,
        0.12323187676185195,
        0.28643482684890953,
        0.4696359058370383,
        0.6123012807469986,
        0.7367214928061024,
        0.8448423378590768,
        0.9000585775273667,
        0.896130776949017,
        0.771667665627637,
        0.5974350505352942,
        0.412051678355521,
        0.256529703327891,
        0.15927513112856123,
        0.14245046320726573,
        0.14631666456213988,
        0.16918877200953636,
        0.1587826571553084,
        0.10555595440473782,
        0.06406797125271543,
        0.06677017630052864,
        0.06359106526367332,
        0.042148220075788695,
        0.00981349922518492,
        0.0036327551122999394,
        0.0018979610351919152,
        0.0017008223093808775,
        0.0009443991373829575,
        0.0007538294759838572,
        0.0016531394301382573,
        0.002197393217321524
      ],
      "range": 1
    }
  }
]
