[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA S (Typ 007) / prf-solomatov-pred-leica-s-typ-007-81ded7d37440@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA S (Typ 007) / prf-solomatov-pred-leica-s-typ-007-81ded7d37440@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000537625792453 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28494167; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.014509344342299953,
        0.02462745702201899,
        0.02432114040008526,
        0.0010687321642861806,
        0.0009120788906470833,
        0.008017657251277663,
        0.019601754312367346,
        0.02957624296870931,
        0.04950060129850436,
        0.04984371985855984,
        0.04929928655222664,
        0.05853375218176835,
        0.07234867092406884,
        0.08062763863214531,
        0.07944288926585233,
        0.0962133797738004,
        0.14438076170867833,
        0.2753558433894528,
        0.44516343558532767,
        0.5146968244829352,
        0.47964548381662353,
        0.4196310187930341,
        0.3465699041423619,
        0.2792879044499245,
        0.2189183590188827,
        0.1621639002601696,
        0.11683489785502736,
        0.07142657716263288,
        0.038375918925689555,
        0.014938336906698803,
        0.008206558601474973
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA S (Typ 007) / prf-solomatov-pred-leica-s-typ-007-81ded7d37440@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA S (Typ 007) / prf-solomatov-pred-leica-s-typ-007-81ded7d37440@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000537625792453 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28494167; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.021095109571022026,
        0.03207414987519478,
        0.058680158410433045,
        0.09130669616827927,
        0.11848149769804403,
        0.13677842454952663,
        0.18195143161268304,
        0.2835293698098266,
        0.39724837206740127,
        0.5137204182089304,
        0.6688287002739896,
        0.8518342044682821,
        0.9716516001867492,
        1,
        0.9609252242683499,
        0.8732268416390434,
        0.7563673044281058,
        0.6090419605294422,
        0.4581853118606152,
        0.3110143075473681,
        0.18730397874063137,
        0.09805675569077515,
        0.06003279508783947,
        0.04394401910565131,
        0.03415363920688575,
        0.025684856888024188,
        0.027809774907774826,
        0.016090372754473187,
        0.008397028529919618,
        0.007642783231358559,
        0.000524683665457365
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA S (Typ 007) / prf-solomatov-pred-leica-s-typ-007-81ded7d37440@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA S (Typ 007) / prf-solomatov-pred-leica-s-typ-007-81ded7d37440@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000537625792453 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28494167; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.059952032068528276,
        0.13695216655668682,
        0.32690657187419986,
        0.5490787665337766,
        0.7031494359721221,
        0.8035537924500673,
        0.8792451482072287,
        0.8995042418719027,
        0.8647999343163814,
        0.7482846018331846,
        0.5709335458025497,
        0.3871706608116204,
        0.22563220368251835,
        0.11382236581964303,
        0.0752544810311528,
        0.05537937769381489,
        0.05929186132074981,
        0.057600743953801485,
        0.04639468504021458,
        0.0399617568354027,
        0.04217700363025177,
        0.043008572797994235,
        0.02677321956862712,
        0.00679136327673939,
        0.00005718920307882662,
        0.000023268360530393142,
        0.00012856181370011412,
        0.00008670786027000784,
        0.0000029990866252401354,
        0.00006801232962033492,
        0.00099213889034101
      ],
      "range": 1
    }
  }
]
