    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica V LUX 2 / prf-solomatov-pred-leica-v-lux-2-b2d7fff5d3fe@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica V LUX 2 / prf-solomatov-pred-leica-v-lux-2-b2d7fff5d3fe@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26210392 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26210392; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.012190412871352706,
        0.022902515155057583,
        0.024618632182227568,
        0.0013552731298333883,
        0.0000010545766732523498,
        0.012560130729826553,
        0.03930557009601383,
        0.06397923388555196,
        0.10276596015809303,
        0.10814582628142304,
        0.09867549481900156,
        0.09222104728536681,
        0.08549368510016944,
        0.054822033947451075,
        0.011479393364280855,
        0.004623040738955754,
        0.04115961714727502,
        0.26518851759256407,
        0.6335363851101502,
        0.8048683514538815,
        0.7586984200770444,
        0.6810186585534471,
        0.583162968337139,
        0.5002041556646692,
        0.42228901040472805,
        0.3426375309457409,
        0.2680611568113899,
        0.17804813449566112,
        0.09703641212233682,
        0.03442934771826381,
        0.028397267007681533
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica V LUX 2 / prf-solomatov-pred-leica-v-lux-2-b2d7fff5d3fe@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica V LUX 2 / prf-solomatov-pred-leica-v-lux-2-b2d7fff5d3fe@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26210392 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26210392; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.020390950276516277,
        0.032902747124117795,
        0.06247361351940101,
        0.09736991342975718,
        0.13468012992709152,
        0.17884883217313194,
        0.2463379792259498,
        0.3586112714376801,
        0.495391217346158,
        0.618128221813699,
        0.7463118064010641,
        0.890606672345839,
        0.9801398620821847,
        1,
        0.9709473250152079,
        0.903540931398508,
        0.8109080932478996,
        0.6818344800031988,
        0.5373882618771975,
        0.39871923319574926,
        0.28176110452678466,
        0.19337095759575057,
        0.139847324679463,
        0.09895934406475111,
        0.06800261514593144,
        0.044359367078523664,
        0.0324277256135658,
        0.01595129138091487,
        0.008950375484655094,
        0.00819423685078804,
        0.002927410013554929
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica V LUX 2 / prf-solomatov-pred-leica-v-lux-2-b2d7fff5d3fe@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica V LUX 2 / prf-solomatov-pred-leica-v-lux-2-b2d7fff5d3fe@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26210392 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26210392; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04664437296473856,
        0.1115903112017554,
        0.2634525649215777,
        0.447812493609405,
        0.5701227589423309,
        0.6543824678394737,
        0.7146790860663206,
        0.7284772009514394,
        0.7001106660289552,
        0.6287919692311356,
        0.518783542039356,
        0.4140197292737934,
        0.3120153639823472,
        0.23497598586087534,
        0.1891572243558967,
        0.15203289214445934,
        0.12514256940529545,
        0.10645594312362822,
        0.09757413395419649,
        0.07017876726147401,
        0.03837216551358713,
        0.015914824928982368,
        0.005289731263843745,
        0.007215640269706764,
        0.010054249474788474,
        0.010464753827413189,
        0.013222601935903897,
        0.008783817502614994,
        0.005417306997926624,
        0.0026242032931060324,
        0.0023679699258217883
      ],
      "range": 1
    }
  }
]