    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA X (Typ 113) / prf-solomatov-pred-leica-x-typ-113-939ac60a9c8b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA X (Typ 113) / prf-solomatov-pred-leica-x-typ-113-939ac60a9c8b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26798648 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26798648; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.009710940268329955,
        0.021729280895066046,
        0.025098508700886698,
        0.00006579523713285834,
        0.015206691397267501,
        0.03237239057731569,
        0.05256955873296294,
        0.06846311799013144,
        0.09464169610347506,
        0.09297107451092308,
        0.07866488264631856,
        0.0680047627775849,
        0.06184824323973358,
        0.040721128916652805,
        0.013709022186492392,
        0.01181407173973851,
        0.048880189776737984,
        0.24698328064908345,
        0.5599145897210934,
        0.7102533680057291,
        0.6763695690916944,
        0.6160831322535375,
        0.5291140060498574,
        0.4541064385039125,
        0.38412577753922506,
        0.31131311176593685,
        0.24448655021701093,
        0.1645578351564601,
        0.09562232393216254,
        0.03965889062761673,
        0.024531341282590075
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA X (Typ 113) / prf-solomatov-pred-leica-x-typ-113-939ac60a9c8b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA X (Typ 113) / prf-solomatov-pred-leica-x-typ-113-939ac60a9c8b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26798648 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26798648; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01885404927890392,
        0.029960600997483152,
        0.06072456714980546,
        0.09821522712638339,
        0.1398529507906518,
        0.1768124757637027,
        0.23379657063296624,
        0.3317384518801097,
        0.4485565465839918,
        0.5665874636660775,
        0.7046387937182502,
        0.8641458330285915,
        0.9690924333197704,
        1,
        0.9735308288686801,
        0.9076487739232217,
        0.8108974378110417,
        0.6748777027856031,
        0.5228697731318386,
        0.3826279594403419,
        0.26684424527685124,
        0.17792662525363218,
        0.1254437611927288,
        0.08631085045782906,
        0.056087527251374766,
        0.03353054975012172,
        0.025066827998188563,
        0.01071778695701365,
        0.005599008950003746,
        0.006380043873855128,
        0.0006365728972595931
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA X (Typ 113) / prf-solomatov-pred-leica-x-typ-113-939ac60a9c8b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA X (Typ 113) / prf-solomatov-pred-leica-x-typ-113-939ac60a9c8b@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26798648 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26798648; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04539223023489841,
        0.11295475428461912,
        0.2651929157023145,
        0.4498319094306548,
        0.5854283768345327,
        0.6820281381359238,
        0.7574705634403645,
        0.7867101355262399,
        0.7731543397263921,
        0.6885257047295819,
        0.5538851064426832,
        0.41086425703266816,
        0.2705012208078556,
        0.1646815167690549,
        0.10989262219497042,
        0.06957250231429585,
        0.05211765160690195,
        0.047828166555268004,
        0.05094257740166593,
        0.040104918725750636,
        0.0178420590471579,
        0.0031170344862173644,
        0.0015554188778478673,
        0.0021027398844896948,
        0.006887812773241396,
        0.00988588230271915,
        0.0138928870590785,
        0.00848978202183931,
        0.005189510306639349,
        0.002602556666291523,
        0.002005128766197459
      ],
      "range": 1
    }
  }
]