[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA X (Typ 113) / prf-solomatov-pred-leica-x-typ-113-939ac60a9c8b@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA X (Typ 113) / prf-solomatov-pred-leica-x-typ-113-939ac60a9c8b@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000505634867925 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26798648; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.012866995855537189,
        0.02808907042532928,
        0.03167192764635702,
        0.00008109645507073236,
        0.018317151001254035,
        0.03812748223550514,
        0.06056927419232686,
        0.07720309049950991,
        0.1045002061142537,
        0.10056054998120251,
        0.08338477560509767,
        0.07067161621984312,
        0.06303763253280537,
        0.040721128916652805,
        0.01345515140526105,
        0.011384469131020746,
        0.04626160818155559,
        0.2296511206035337,
        0.5116460906072059,
        0.6380242119373499,
        0.5974597860309967,
        0.5352853444170079,
        0.4523071342039103,
        0.3820260514397994,
        0.31810415952467075,
        0.25383992190145616,
        0.19633010850759966,
        0.1301726158700356,
        0.07452916424124433,
        0.030462626134256328,
        0.01857372982824677
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA X (Typ 113) / prf-solomatov-pred-leica-x-typ-113-939ac60a9c8b@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA X (Typ 113) / prf-solomatov-pred-leica-x-typ-113-939ac60a9c8b@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000505634867925 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26798648; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.024981615294547694,
        0.03872955738699042,
        0.07662862045094498,
        0.12105597762089114,
        0.16845923617964875,
        0.20824580478836097,
        0.26937430964233067,
        0.37408804148182584,
        0.4952811868531576,
        0.6128395015163695,
        0.7469171213413452,
        0.8980339049120656,
        0.9877288262682274,
        1,
        0.9555024801859268,
        0.8746433639623772,
        0.767456503642593,
        0.627517863993631,
        0.47779479268943864,
        0.34371664153115455,
        0.23571241666121856,
        0.15459198587610662,
        0.10723418295507461,
        0.07261071546452286,
        0.046447483505044726,
        0.027340294411637708,
        0.020129422483393847,
        0.00847824938390632,
        0.004363933446326448,
        0.00490061341035249,
        0.0004819766222108347
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA X (Typ 113) / prf-solomatov-pred-leica-x-typ-113-939ac60a9c8b@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA X (Typ 113) / prf-solomatov-pred-leica-x-typ-113-939ac60a9c8b@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000505634867925 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26798648; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06014470506124039,
        0.14601468236792225,
        0.33464820314815874,
        0.5544439813912722,
        0.7051750902779599,
        0.8032775849156435,
        0.8727378230943329,
        0.8871412166572491,
        0.8536912501145579,
        0.7447318847075068,
        0.5871182128292441,
        0.4269765808378708,
        0.2757031673618528,
        0.16468151676905488,
        0.1078575736358043,
        0.06704259313923054,
        0.0493256345565322,
        0.044471803989986035,
        0.04655097590152231,
        0.03602645241465735,
        0.015760485491656144,
        0.0027082430781888572,
        0.0013296322665473704,
        0.0017689716488564098,
        0.00570396995284053,
        0.00806079633914023,
        0.011156409305017583,
        0.006715797718768408,
        0.00404476538605714,
        0.001999065265412329,
        0.0015181689229780758
      ],
      "range": 1
    }
  }
]
