    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA X VARIO (Typ 107) / prf-solomatov-pred-leica-x-vario-typ-107-b1d0369e9f2a@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA X VARIO (Typ 107) / prf-solomatov-pred-leica-x-vario-typ-107-b1d0369e9f2a@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000499031396226 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26448664; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.010562045374012086,
        0.027277671779933992,
        0.033633964064264624,
        0.00039685054932110377,
        0.013373741349038891,
        0.03451565821581343,
        0.05835906231160797,
        0.07868772807772309,
        0.10483813489281224,
        0.09808299487301907,
        0.07790922233349859,
        0.05759313063163846,
        0.04211716276249196,
        0.01324904274938046,
        0.000063940480796784,
        0.0029351937157822547,
        0.0219967551372079,
        0.21388661293625733,
        0.5049027911527806,
        0.6464411381091731,
        0.6158400099150566,
        0.5541380377659832,
        0.47220598680791465,
        0.40500569119273633,
        0.34227499520391647,
        0.2793290753159229,
        0.2194289278599662,
        0.1475211940959433,
        0.08406149161480608,
        0.03265459205551303,
        0.019452554206248644
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA X VARIO (Typ 107) / prf-solomatov-pred-leica-x-vario-typ-107-b1d0369e9f2a@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA X VARIO (Typ 107) / prf-solomatov-pred-leica-x-vario-typ-107-b1d0369e9f2a@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000499031396226 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26448664; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.023672912344457172,
        0.039420433854658876,
        0.08127311909015966,
        0.13395685106007796,
        0.18758493640909252,
        0.22711361064505103,
        0.28040969002869265,
        0.371410904262157,
        0.4780155319628495,
        0.5879589577139831,
        0.7225527746883548,
        0.8826756514238373,
        0.9810518086602087,
        1,
        0.962813317373079,
        0.8824405614246115,
        0.7801547502415569,
        0.640505142272805,
        0.49206775460932733,
        0.3577526682876711,
        0.25213750935270934,
        0.17368553377933055,
        0.12433678874619515,
        0.08532379784163995,
        0.05603362062777538,
        0.032759347809663386,
        0.02193956026961467,
        0.00929805524787481,
        0.0047264027878574835,
        0.004752653542979209,
        0.002020976479460091
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA X VARIO (Typ 107) / prf-solomatov-pred-leica-x-vario-typ-107-b1d0369e9f2a@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA X VARIO (Typ 107) / prf-solomatov-pred-leica-x-vario-typ-107-b1d0369e9f2a@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000499031396226 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26448664; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06632822153134087,
        0.15251345020678547,
        0.3475927879435746,
        0.5715388871200486,
        0.7230359434137288,
        0.8245295515367682,
        0.8993117186660495,
        0.9190532053162275,
        0.8826826060729066,
        0.7612574483681956,
        0.5894417910863096,
        0.41463346637448745,
        0.25638012304777397,
        0.14044197468726585,
        0.08558263577236935,
        0.04968450738450085,
        0.03855397633965287,
        0.03972689960060915,
        0.04247773646753367,
        0.03179459272498603,
        0.017049768941070142,
        0.006816289156962493,
        0.004374719578493887,
        0.0014995811904759745,
        0.0006522679220914523,
        0.000004803877184059714,
        0.00001856898531182268,
        0.000006829582856767584,
        0.000004139316361955327,
        0.00009235100741638184,
        0.0005526696357895431
      ],
      "range": 1
    }
  }
]