[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya M18 / prf-solomatov-pred-mamiya-m18-39a4a51185f6@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya M18 / prf-solomatov-pred-mamiya-m18-39a4a51185f6@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000537171132075 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2847007; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.009315467085258308,
        0.01688140496232042,
        0.032149117083643416,
        0.031283166480970494,
        0.06589449495877281,
        0.07384864042210723,
        0.06915843168999401,
        0.048001557649242826,
        0.030620793389338347,
        0.01925208688368135,
        0.010519911928562171,
        0.014181261901344389,
        0.028645100667256746,
        0.04077742344855492,
        0.046587298455822136,
        0.06066190736766398,
        0.09419566991129381,
        0.1919409685514056,
        0.3388034788330584,
        0.4362419706266253,
        0.42330392759835156,
        0.38599751351184586,
        0.3256700780628512,
        0.27352366331624195,
        0.2194170404217482,
        0.17485179834336684,
        0.13097689332032278,
        0.08710869465120241,
        0.050656635712728576,
        0.020198682203165782,
        0.011323276288798326
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya M18 / prf-solomatov-pred-mamiya-m18-39a4a51185f6@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya M18 / prf-solomatov-pred-mamiya-m18-39a4a51185f6@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000537171132075 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2847007; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.020267507596574225,
        0.02790001280506074,
        0.04874854205704112,
        0.07914904367827295,
        0.09421573443779571,
        0.10244358318909805,
        0.14910413088124688,
        0.25852361982922734,
        0.38333333991919705,
        0.5131712012091353,
        0.6731092912662315,
        0.8525638094087347,
        0.9690399885807204,
        1,
        0.9619537712307593,
        0.8815435137832308,
        0.7649544140314974,
        0.6050435520777349,
        0.4279640780166923,
        0.2729343414008025,
        0.1638895311813424,
        0.08573790265229185,
        0.0505153487901165,
        0.024891396585066464,
        0.005163864147506487,
        0.000007213180449071333,
        0.00003248379337360678,
        0.000021319921315220018,
        0.00000899585429437259,
        0.00003927820685199315,
        0.00011074890427536207
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya M18 / prf-solomatov-pred-mamiya-m18-39a4a51185f6@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya M18 / prf-solomatov-pred-mamiya-m18-39a4a51185f6@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000537171132075 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2847007; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06207050790531952,
        0.14752370497568404,
        0.34390707420777245,
        0.5623394796302646,
        0.7197510754276333,
        0.8343494195053885,
        0.9221591649848726,
        0.9556857728507107,
        0.9363556586209073,
        0.808285377791986,
        0.6250612885742818,
        0.4265705628512233,
        0.2511025809803878,
        0.1288259143725323,
        0.07749627031969858,
        0.044822225203201435,
        0.035722670773201466,
        0.035826194334131096,
        0.03610704468430083,
        0.02613626732106706,
        0.0007612192383088627,
        0.00003065503527037342,
        0.000030213162511117932,
        0.0000017505816091207696,
        0.00000948439893412626,
        0.00004238771226711474,
        0.00001233299002223824,
        0.004345618104970977,
        0.0036494865536705326,
        0.0007155955568146794,
        0.0018463117472389172
      ],
      "range": 1
    }
  }
]
