    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya M22 / prf-solomatov-pred-mamiya-m22-4746e3a0e59f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya M22 / prf-solomatov-pred-mamiya-m22-4746e3a0e59f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.29686716 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.29686716; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.005657348896388539,
        0.010438144454913773,
        0.016789275715104357,
        0.012737935378234493,
        0.02573365945899843,
        0.03139825907318276,
        0.03665756427891856,
        0.03991553663261373,
        0.04649714707413242,
        0.05120738851680327,
        0.0625771169839062,
        0.0856277703468447,
        0.11526881585689706,
        0.14404730048281528,
        0.16175177476686878,
        0.17980455635443138,
        0.20483319879504353,
        0.250887602387546,
        0.3136688477095277,
        0.36129701917854434,
        0.3425727183835356,
        0.30099722044028043,
        0.24673625065163823,
        0.1968610135253761,
        0.14709607489087037,
        0.10406803500932875,
        0.07079012713969439,
        0.042964657997199826,
        0.0219970373280763,
        0.00927609170377754,
        0.004032939514091083
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya M22 / prf-solomatov-pred-mamiya-m22-4746e3a0e59f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya M22 / prf-solomatov-pred-mamiya-m22-4746e3a0e59f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.29686716 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.29686716; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015048269401034455,
        0.02155068819333199,
        0.04051027402289967,
        0.06478832822060884,
        0.08090164974798827,
        0.0916375357921031,
        0.1322600755166048,
        0.23093313857955858,
        0.34544305944786885,
        0.4697046315261007,
        0.6298642126667026,
        0.8195339962830513,
        0.9530999656546718,
        1,
        0.9732426112743491,
        0.8942931579228905,
        0.7818264573285909,
        0.6347375708380811,
        0.473208420897751,
        0.3030824965617618,
        0.15769441456576064,
        0.05289667270707882,
        0.015376569102490151,
        0.009386122398988153,
        0.012606461085153372,
        0.012767367060741915,
        0.029693570686633038,
        0.01741681026624838,
        0.00022062706430714664,
        0.009670173689807925,
        0.0012945151292584871
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya M22 / prf-solomatov-pred-mamiya-m22-4746e3a0e59f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya M22 / prf-solomatov-pred-mamiya-m22-4746e3a0e59f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.29686716 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.29686716; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.041916172203082344,
        0.11200142851772488,
        0.2645451251664212,
        0.4334229491736304,
        0.5651022497739393,
        0.6758551198455227,
        0.7644552196342633,
        0.8112061974116638,
        0.815573538009391,
        0.7264399336053203,
        0.5731438263498057,
        0.39528808103934426,
        0.2257115101582809,
        0.10329760287395884,
        0.05672734565857672,
        0.026988455038273684,
        0.02323102191566086,
        0.017938944812892068,
        0.010526463082006107,
        0.013524985384035067,
        0.020528094114552784,
        0.021612273651285645,
        0.009833547098978546,
        0.00002078424572121753,
        0.000049544169856982495,
        0.000004406999076624036,
        0.000038536330525747605,
        0.000016039546105402832,
        0.016117394055981133,
        0.00003945135763753727,
        0.004122754433329709
      ],
      "range": 1
    }
  }
]