[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya ZD / prf-solomatov-pred-mamiya-zd-9562b0a77b42@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya ZD / prf-solomatov-pred-mamiya-zd-9562b0a77b42@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27658716 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27658716; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.009563747283134909,
        0.014871315790653478,
        0.0025576060725306265,
        0.002176380494307834,
        0.0002570447232619186,
        0.0003603350567683619,
        0.0011483204064859699,
        0.0008958370663338096,
        0.0006628223088880915,
        0.0020585037280834006,
        0.01855109796130811,
        0.09938502206682336,
        0.18332423674331086,
        0.24165966344930837,
        0.25165380055965,
        0.2696888026183139,
        0.32485719872173385,
        0.4991098285256626,
        0.7054599714607143,
        0.746862291076708,
        0.6581399512544256,
        0.5391528659537196,
        0.43237469881103663,
        0.3680959376422246,
        0.298560374241523,
        0.22727273384635785,
        0.17783003014312015,
        0.11695734538074724,
        0.06245762095391558,
        0.03020621058475744,
        0.013562286477796006
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya ZD / prf-solomatov-pred-mamiya-zd-9562b0a77b42@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya ZD / prf-solomatov-pred-mamiya-zd-9562b0a77b42@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27658716 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27658716; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.018614603440015073,
        0.029222361587573333,
        0.04497948133239446,
        0.05834786401509021,
        0.0717871972075638,
        0.09986060090425022,
        0.16284486958830627,
        0.29252911089582034,
        0.45537695965351394,
        0.5956810504146324,
        0.7406225220288607,
        0.8933652596165347,
        0.9863221777901766,
        1,
        0.9530015059267394,
        0.8586408349541605,
        0.7439076709128507,
        0.6267156436329149,
        0.5070447232619186,
        0.3548809351815175,
        0.19008415285799962,
        0.06738107076264856,
        0.01981956067664168,
        0.031186006609995928,
        0.05340649218857448,
        0.0702443851695791,
        0.09607179884995384,
        0.07371577914173601,
        0.04217281814528194,
        0.028048868935202923,
        0.01715445359068729
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya ZD / prf-solomatov-pred-mamiya-zd-9562b0a77b42@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya ZD / prf-solomatov-pred-mamiya-zd-9562b0a77b42@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27658716 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27658716; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.03825305918033216,
        0.09938995721999531,
        0.24599070325607306,
        0.43295292521894363,
        0.5444621868925513,
        0.6049199825472736,
        0.6447614921820667,
        0.6328528771906838,
        0.5789794435866076,
        0.505331953948983,
        0.42250507941149545,
        0.3559969667427801,
        0.3064576461177735,
        0.29038737734607784,
        0.2927060316176644,
        0.29361243667276526,
        0.27499566501930167,
        0.20637020894245417,
        0.1209339110318787,
        0.0718125599178212,
        0.05916541462011469,
        0.04526140331315452,
        0.028100412542650208,
        0.0007628042820209007,
        0.0012376707942624667,
        0.001448345794504705,
        0.0012340865714807587,
        0.001635889966837217,
        0.0008150236258255807,
        0.00003419404573950577,
        0.0000433594169736585
      ],
      "range": 1
    }
  }
]
