[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7 / prf-solomatov-pred-minolta-dimage-7-fc7c31317c0f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7 / prf-solomatov-pred-minolta-dimage-7-fc7c31317c0f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00052038409434 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27580357; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011772018143202426,
        0.02399095842192255,
        0.03168428435533028,
        0.014003426592743626,
        0.049016477890076224,
        0.061600994585466105,
        0.06267053995049417,
        0.04800199047614044,
        0.03886041061457858,
        0.030126651007454326,
        0.020184792952462508,
        0.020615325425336617,
        0.031370293789999774,
        0.03241754267357743,
        0.02364930368807476,
        0.030319919090506065,
        0.07522086377582837,
        0.23133803067466496,
        0.44964870569246823,
        0.5643433212697878,
        0.545489609990666,
        0.49080896804116964,
        0.41440023372782214,
        0.3545049666935979,
        0.29546117674890865,
        0.24052532582686123,
        0.1879493863782265,
        0.12805171286303077,
        0.07627089720156312,
        0.02957149891502308,
        0.01875536900617867
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7 / prf-solomatov-pred-minolta-dimage-7-fc7c31317c0f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7 / prf-solomatov-pred-minolta-dimage-7-fc7c31317c0f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00052038409434 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27580357; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.02115195798589554,
        0.031089409384950948,
        0.0595634443572942,
        0.0966369561074648,
        0.1257736846916086,
        0.14448280870492158,
        0.19339477572831051,
        0.30306211093518326,
        0.4313251947451828,
        0.5609448064942801,
        0.7111528657877779,
        0.8778090408869688,
        0.9810454020982007,
        1,
        0.9591035307402939,
        0.8791144594815664,
        0.7680317715404689,
        0.6128280406359815,
        0.4483347558078981,
        0.3065326430986212,
        0.19952316848787224,
        0.12201752393893246,
        0.08115230927903953,
        0.048554019919851046,
        0.023735247573572017,
        0.005828595045156456,
        0.00002799284600861535,
        0.00002131957276911613,
        0.000008464730617988055,
        0.0012157349490814597,
        0.00006704863433887282
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7 / prf-solomatov-pred-minolta-dimage-7-fc7c31317c0f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7 / prf-solomatov-pred-minolta-dimage-7-fc7c31317c0f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00052038409434 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27580357; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.061524514485073574,
        0.14840685311810511,
        0.3453810405717374,
        0.567648152548367,
        0.723781511503739,
        0.8261638624426314,
        0.9022370806370889,
        0.9125935951059723,
        0.8675305988606312,
        0.7390484555692285,
        0.5661704944573415,
        0.39372130722472903,
        0.24361325205248294,
        0.1411581438195307,
        0.09777367047993749,
        0.06757283954597898,
        0.055007953926878364,
        0.046148652164088595,
        0.03422310662171132,
        0.017102321858012255,
        0.0000069647449632359725,
        0.000005019255676879851,
        0.00001123881639338812,
        0.00002447691419462162,
        0.00000323839614254268,
        0.0000029917865876009564,
        0.000025074357790000305,
        0.00000587224488423074,
        0.00006609238324942639,
        0.0003676511516690214,
        0.0008298661735441432
      ],
      "range": 1
    }
  }
]
