[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7Hi / prf-solomatov-pred-minolta-dimage-7hi-7621aac35815@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7Hi / prf-solomatov-pred-minolta-dimage-7hi-7621aac35815@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2715304 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2715304; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01032949275661215,
        0.019219632497871324,
        0.026814017877924534,
        0.0049195117747405075,
        0.028658092427219933,
        0.04283647429532752,
        0.052838632433053534,
        0.05107425540565624,
        0.05626926856072101,
        0.053070004316275454,
        0.04377013402550874,
        0.04325593009106899,
        0.05071146729795264,
        0.03942897001588036,
        0.01622559021015695,
        0.017536469949589437,
        0.05861041710246808,
        0.24757691956407094,
        0.5534775848302805,
        0.7073761538302894,
        0.6758449882591414,
        0.6109545745154134,
        0.5228970310506669,
        0.4479165132154631,
        0.3780264751202812,
        0.30989889161581907,
        0.24288357399392482,
        0.16801859018364057,
        0.09630236614390138,
        0.037603992039197086,
        0.02656886374417008
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7Hi / prf-solomatov-pred-minolta-dimage-7hi-7621aac35815@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7Hi / prf-solomatov-pred-minolta-dimage-7hi-7621aac35815@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2715304 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2715304; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015723009283675052,
        0.027512386826668393,
        0.05273220236113525,
        0.08478666108840852,
        0.11459283748707327,
        0.1421252058701346,
        0.1961219811851638,
        0.2975114020382248,
        0.423877326443006,
        0.5468753406616718,
        0.6918981447381214,
        0.8572196704310088,
        0.966315742178408,
        1,
        0.9784775480019916,
        0.9118585616932764,
        0.816202826644825,
        0.6736351436155951,
        0.5086886772162527,
        0.36115075881006325,
        0.2461355892378901,
        0.16082929572526686,
        0.11146770306381901,
        0.07309577859422002,
        0.04330574035172489,
        0.020693605577865315,
        0.011177776779321948,
        0.0013390478561516501,
        0.0003500481714018025,
        0.00394439996405559,
        0.0023281691479112468
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7Hi / prf-solomatov-pred-minolta-dimage-7hi-7621aac35815@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7Hi / prf-solomatov-pred-minolta-dimage-7hi-7621aac35815@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2715304 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2715304; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04603207964927684,
        0.11053059988863125,
        0.2675027547560052,
        0.4573688839260724,
        0.5914771973966819,
        0.6840402032332291,
        0.7552101716787513,
        0.7759100638455215,
        0.7471735024881192,
        0.654886892959315,
        0.5200976023310834,
        0.383219042876967,
        0.2593582707497945,
        0.16955377372110084,
        0.1284834294797194,
        0.0950133613031911,
        0.07714350216403025,
        0.06223642361960208,
        0.049363901795158115,
        0.027803242657175768,
        0.000042801387984549794,
        0.00010638676921626454,
        0.00028425178175261405,
        0.000004001106321796749,
        0.00011389604994505219,
        0.000017553101236546625,
        0.000021352251534266514,
        0.0014195056612445604,
        0.0027748985012359573,
        0.000004851691375993259,
        0.0021240161322636435
      ],
      "range": 1
    }
  }
]
