[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7i / prf-solomatov-pred-minolta-dimage-7i-37f1d7fd677c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7i / prf-solomatov-pred-minolta-dimage-7i-37f1d7fd677c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000509084849057 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26981497; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011932157303947963,
        0.023954035575727704,
        0.03513496075088934,
        0.011877793382317814,
        0.03921403821831882,
        0.056212912789004185,
        0.06321309155742513,
        0.052902406896797594,
        0.05160166744701626,
        0.04132791287091511,
        0.03103737231481263,
        0.024153072628500444,
        0.03108311004332397,
        0.017398887837839393,
        0.000031271322474009456,
        0.0007430279161645142,
        0.046114937647296385,
        0.24726443770746026,
        0.5043415422926618,
        0.6229498336506908,
        0.6019524719724287,
        0.5339365343590833,
        0.45112411425814786,
        0.38408151357759013,
        0.32399611956760593,
        0.2614972281531702,
        0.2032022402746459,
        0.14183398791412447,
        0.08227771811222205,
        0.02996502284187729,
        0.023469725038395232
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7i / prf-solomatov-pred-minolta-dimage-7i-37f1d7fd677c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7i / prf-solomatov-pred-minolta-dimage-7i-37f1d7fd677c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000509084849057 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26981497; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.020642389023114622,
        0.0344573112997924,
        0.06542694080846802,
        0.10393851050230185,
        0.13750185998676326,
        0.16124984128526634,
        0.21209501072724668,
        0.32030809854620007,
        0.4442434186935589,
        0.5678215076844124,
        0.7105184541836208,
        0.8778865179712007,
        0.9776691240838691,
        1,
        0.9641389238514633,
        0.8861736558339828,
        0.7780979803095646,
        0.6247800750009626,
        0.4599418912383065,
        0.3188963595864057,
        0.21228973952038324,
        0.13808917128118348,
        0.09392916763805617,
        0.05946953896967198,
        0.03166007413571234,
        0.013104973661708303,
        0.003027974734393767,
        0.00002462446156419325,
        0.00002030400587222465,
        0.0009574443370301647,
        0.00005613123245163158
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7i / prf-solomatov-pred-minolta-dimage-7i-37f1d7fd677c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7i / prf-solomatov-pred-minolta-dimage-7i-37f1d7fd677c@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000509084849057 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26981497; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.05763192040456466,
        0.13454123132116402,
        0.3346555524963751,
        0.5798696641869489,
        0.7342461509152669,
        0.8314661990606214,
        0.9026743320657374,
        0.9135163224966213,
        0.8606787682746687,
        0.7352833881163912,
        0.5670567500387396,
        0.4002813075211956,
        0.2568917203775724,
        0.158000154698607,
        0.11539982738156807,
        0.08323615509884086,
        0.07047157069210377,
        0.05530562920289607,
        0.04060392514480419,
        0.019855236349562072,
        0.000052935894117859125,
        0.00005430048478085241,
        0.000016932443896406062,
        0.000014025497453322087,
        0.00004473796530127665,
        0.00007244538763845347,
        0.000035304338404854844,
        0.00006943629775996094,
        0.000035873287316772947,
        0.0001293338260338348,
        0.0013276570718073945
      ],
      "range": 1
    }
  }
]
