[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D5000 / prf-solomatov-pred-nikon-d5000-0be7037a0ef0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D5000 / prf-solomatov-pred-nikon-d5000-0be7037a0ef0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000536432830189 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2843094; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.009032306986684226,
        0.019694130288529538,
        0.03519881065520605,
        0.024491965156989717,
        0.06257227529393874,
        0.07582316604531698,
        0.07769928587597205,
        0.0607121796992246,
        0.05050926722202409,
        0.03703702001683909,
        0.025847118259192278,
        0.029426639828741125,
        0.04469563819178359,
        0.05546082542469578,
        0.060320047325072484,
        0.07573682275845836,
        0.11375638049854943,
        0.22965125687941232,
        0.3992665579022058,
        0.5014100841178362,
        0.48296043559117874,
        0.4371240754141699,
        0.3682025791438437,
        0.3116047047157802,
        0.25435509200100315,
        0.20421108590743856,
        0.15479078255995588,
        0.10401959987904287,
        0.059768518598979525,
        0.023078601585333505,
        0.015337092618112523
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D5000 / prf-solomatov-pred-nikon-d5000-0be7037a0ef0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D5000 / prf-solomatov-pred-nikon-d5000-0be7037a0ef0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000536432830189 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2843094; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.019663480041461876,
        0.028953648864882296,
        0.05726855554781751,
        0.09395343487649167,
        0.1214564034975469,
        0.13594614958992643,
        0.18210416416824038,
        0.2862899530836267,
        0.4065441037416749,
        0.535291165906163,
        0.6923767135381385,
        0.8667835939628158,
        0.9744900612339396,
        1,
        0.9562156762498362,
        0.8727031792572715,
        0.7545524982139681,
        0.5943863152842174,
        0.42105978678449457,
        0.26976802235969405,
        0.15876799829106367,
        0.08040981369327185,
        0.046209471203759234,
        0.02166550043217505,
        0.006238801251822839,
        0.000027930224228631534,
        0.000012712476688062268,
        0.00005729107764445271,
        0.000011762327311683101,
        0.0012693594586987156,
        0.000018959172517184246
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D5000 / prf-solomatov-pred-nikon-d5000-0be7037a0ef0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D5000 / prf-solomatov-pred-nikon-d5000-0be7037a0ef0@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000536432830189 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2843094; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.062072934626853704,
        0.14179570840952782,
        0.3304493072888701,
        0.5475011313010928,
        0.7077012450648357,
        0.8189115574636491,
        0.9018635920554525,
        0.9189007535976428,
        0.8786924913492132,
        0.7420872414607008,
        0.5582648994370218,
        0.3718384881083088,
        0.21722531117372618,
        0.11012242296596596,
        0.07065283455277949,
        0.04545785094433293,
        0.04136696852091419,
        0.03936189415042883,
        0.03435948868404972,
        0.02141595090013717,
        0.003242885661419098,
        0.000124860339406041,
        0.000023415215504544492,
        0.00002830987437216426,
        0.000013453749297860009,
        0.00001935254897007924,
        0.00003072516623002116,
        0.000012009240269658297,
        0.00009487798529886601,
        0.0002451283439495998,
        0.00047394127062177436
      ],
      "range": 1
    }
  }
]
