    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D5600 / prf-solomatov-pred-nikon-d5600-fd779a25c4aa@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D5600 / prf-solomatov-pred-nikon-d5600-fd779a25c4aa@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000517277622642 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27415714; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016887696505004393,
        0.027814328566207348,
        0.03036461011617887,
        0.00012308656472758482,
        0.01176695498428383,
        0.02840662435014054,
        0.04409959716818832,
        0.0538434189409798,
        0.0746057588694085,
        0.06833751115234458,
        0.05632710120188735,
        0.05119577621883308,
        0.05201728012628086,
        0.03799054804846593,
        0.021477616078677174,
        0.025560707131816313,
        0.07913695317218439,
        0.2642177843891396,
        0.5056483023341763,
        0.6043314497094869,
        0.5686216075447339,
        0.5021964775383928,
        0.4204074278879482,
        0.3480568421916657,
        0.27892098869602666,
        0.2171638647708503,
        0.16097072616489547,
        0.10227115918798499,
        0.05463309869746706,
        0.022713662936391942,
        0.014329797476210698
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D5600 / prf-solomatov-pred-nikon-d5600-fd779a25c4aa@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D5600 / prf-solomatov-pred-nikon-d5600-fd779a25c4aa@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000517277622642 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27415714; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.022339389902447916,
        0.03605952688657173,
        0.07045415372262158,
        0.10916612385993514,
        0.1506925984790395,
        0.1819074758853019,
        0.23262832760168448,
        0.32773018190116127,
        0.44106219596663915,
        0.5518209567918693,
        0.6951121105217248,
        0.8654854099582537,
        0.9745486180774899,
        1,
        0.9633501976275357,
        0.8839035856987312,
        0.7728132141140452,
        0.6252338387124682,
        0.4732283740128267,
        0.331293675936783,
        0.21588476241520949,
        0.13326730889553007,
        0.08915354200431984,
        0.06086408993541742,
        0.042021006923711704,
        0.02588429714769813,
        0.020724767250879062,
        0.011159140621367513,
        0.0044073753007233055,
        0.0056854211949130835,
        0.001516697378632665
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D5600 / prf-solomatov-pred-nikon-d5600-fd779a25c4aa@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D5600 / prf-solomatov-pred-nikon-d5600-fd779a25c4aa@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000517277622642 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27415714; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06099119432016251,
        0.14204699938714335,
        0.32995151126345523,
        0.5512312773072999,
        0.7028821002569415,
        0.803112001144064,
        0.8786590261781032,
        0.8983255035818649,
        0.8643508123358256,
        0.7541239201096755,
        0.5840333058624699,
        0.40614279302967426,
        0.24492274969356287,
        0.13119186317744633,
        0.08349226361094846,
        0.057234590153130954,
        0.05686653093238009,
        0.05468231973081172,
        0.04373494547311632,
        0.03438419814172563,
        0.029772342727726636,
        0.025588691251433635,
        0.012898493895778872,
        0.0009586566233337499,
        0.00006442122441394377,
        0.00004533323435210579,
        0.000012470048066726856,
        0.000014835961502322594,
        0.00002084035068784446,
        0.00007362667312051323,
        0.00002199514107649566
      ],
      "range": 1
    }
  }
]