    "model": "ESTIMATED PHOTON-RESPONSE MODEL / NIKON Z 30 / prf-solomatov-pred-nikon-z-30-c22ce6d1c4f3@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / NIKON Z 30 / prf-solomatov-pred-nikon-z-30-c22ce6d1c4f3@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000487720226415 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.25849172; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.017314501311686117,
        0.029843550425862016,
        0.03043508426866586,
        0.00014656720559469926,
        0.00019792007747869062,
        0.021134185583283758,
        0.050760761311813,
        0.07587010128882814,
        0.1138455792059155,
        0.10386491612314132,
        0.07522702978648602,
        0.04009719442813085,
        0.014887922953735082,
        0.00003577046491082964,
        0.00004108406150193988,
        0.0000073027131461625994,
        0.000009456856103553336,
        0.17676069598412414,
        0.49287902355914587,
        0.6614379730307567,
        0.6448537835821846,
        0.5801953010776337,
        0.4923325284723789,
        0.42685755524700614,
        0.36387802322546353,
        0.2972862305876686,
        0.2374755029372748,
        0.16666954649947263,
        0.09732025914203592,
        0.03556043514073976,
        0.023899353001657905
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / NIKON Z 30 / prf-solomatov-pred-nikon-z-30-c22ce6d1c4f3@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / NIKON Z 30 / prf-solomatov-pred-nikon-z-30-c22ce6d1c4f3@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000487720226415 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.25849172; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.02530820966915304,
        0.04012863375653042,
        0.08057342297260504,
        0.13481542437890298,
        0.1913145533425421,
        0.22661954906030346,
        0.2684315352117679,
        0.3504676240158494,
        0.4507115208564515,
        0.5591042868820333,
        0.6930270300340762,
        0.8591202312960345,
        0.966931752130278,
        1,
        0.9726700014478866,
        0.906718672740184,
        0.8097224158669377,
        0.6688744465020035,
        0.5079360235573903,
        0.3664615187870805,
        0.26655281646932444,
        0.19022334007702738,
        0.13910244466406643,
        0.09080945171117807,
        0.05407334819564047,
        0.024305055621540575,
        0.009488816801395324,
        0.000028394217787826442,
        0.000052351421318936134,
        0.00156404481204732,
        0.000027306955021339062
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / NIKON Z 30 / prf-solomatov-pred-nikon-z-30-c22ce6d1c4f3@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / NIKON Z 30 / prf-solomatov-pred-nikon-z-30-c22ce6d1c4f3@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000487720226415 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.25849172; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06601756653946207,
        0.15429750114786903,
        0.3536284595959389,
        0.5843242744649076,
        0.7426031330379311,
        0.8510651525360701,
        0.9376847654001721,
        0.967909416982486,
        0.9433123235049851,
        0.8195090570571689,
        0.6352760931762147,
        0.44007992846756877,
        0.2647997464796045,
        0.1343205113107685,
        0.07518254936753874,
        0.035593636317353884,
        0.03182516521778172,
        0.043473244605010265,
        0.057858760827806305,
        0.04904055622676641,
        0.023989002368560716,
        0.002368403810343186,
        0.00009441926867634414,
        0.000005204245337419043,
        0.00002969933343029324,
        0.00002289111542915185,
        0.00000730015392931946,
        0.00205469858625178,
        0.0036467435466200075,
        0.0003706803205270498,
        0.0042099106418462574
      ],
      "range": 1
    }
  }
]