[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus C 7070WZ / prf-solomatov-pred-olympus-c-7070wz-838ac4d4db14@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus C 7070WZ / prf-solomatov-pred-olympus-c-7070wz-838ac4d4db14@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28262177 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28262177; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.008365451465398436,
        0.015242045932979613,
        0.021354311453077375,
        0.005508829344604275,
        0.020426413011283596,
        0.0302658248867382,
        0.039151240896976906,
        0.0393334490828502,
        0.04367966770571142,
        0.03809722442825265,
        0.026111116634787195,
        0.022010266583497796,
        0.030024537741731645,
        0.03318515767557467,
        0.030556354522866373,
        0.041932169627272524,
        0.0908027219559201,
        0.25227573233300465,
        0.4735043942297863,
        0.5991312346532965,
        0.589221346961347,
        0.5418281118259219,
        0.4664892587715377,
        0.40264191254622744,
        0.3388892511712739,
        0.2796463980817897,
        0.21941117274865274,
        0.15237419962375862,
        0.09139836963019515,
        0.039142878130018086,
        0.023914625189701416
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus C 7070WZ / prf-solomatov-pred-olympus-c-7070wz-838ac4d4db14@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus C 7070WZ / prf-solomatov-pred-olympus-c-7070wz-838ac4d4db14@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28262177 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28262177; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.014935420579950372,
        0.024654498483963214,
        0.049803367942957824,
        0.08786318902468129,
        0.12057899149099519,
        0.1403062474628193,
        0.18022834192850748,
        0.2663645479256605,
        0.37016067445901285,
        0.489408866132287,
        0.6463159578966617,
        0.8290938097231505,
        0.9528357281181844,
        1,
        0.9761979765394577,
        0.9091710804868287,
        0.8030825084705966,
        0.6444836857401325,
        0.46832998745991866,
        0.31594876785323367,
        0.1978155256758883,
        0.11518539424616864,
        0.0743206653896478,
        0.04501466748297557,
        0.0205274314147845,
        0.002768004035924055,
        0.00004070670316727547,
        0.00006529631457619136,
        0.000008657013930667833,
        0.000733400686012263,
        0.00005865947269384096
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus C 7070WZ / prf-solomatov-pred-olympus-c-7070wz-838ac4d4db14@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus C 7070WZ / prf-solomatov-pred-olympus-c-7070wz-838ac4d4db14@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.28262177 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28262177; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04416154848934673,
        0.11031397192084673,
        0.2702199692543147,
        0.45621467872060956,
        0.5913360460519372,
        0.695994968823527,
        0.7779574800624878,
        0.8030288324922741,
        0.774670189065761,
        0.6564753309697268,
        0.490095932808007,
        0.3194247031996155,
        0.17550986960417098,
        0.07500822035047053,
        0.04180551625587796,
        0.023675106485958247,
        0.028473991936289977,
        0.03790942927008065,
        0.04012775802798206,
        0.03329253086200684,
        0.022441215338790073,
        0.011766619747657798,
        0.002656583532117855,
        0.000011205529920784234,
        0.000013636606974756404,
        0.000020038845556731173,
        0.000049497464402689146,
        0.000006922226833410604,
        0.0000037007605606602773,
        0.0001465341328801387,
        0.0008831914116170172
      ],
      "range": 1
    }
  }
]
