[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M1 Mark III / prf-solomatov-pred-olympus-e-m1-mark-iii-9cc4ad06c4de@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M1 Mark III / prf-solomatov-pred-olympus-e-m1-mark-iii-9cc4ad06c4de@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2705364 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2705364; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.013527716048561303,
        0.02515636712841599,
        0.02857161069637949,
        0.00026780192979576866,
        0.009747289459015497,
        0.02697480523877748,
        0.05070734289359953,
        0.06753600254901003,
        0.09698869357321233,
        0.09479664473985756,
        0.08099688618611026,
        0.07078697358285244,
        0.058778940652718076,
        0.026481522264656436,
        0.00007899010632210675,
        0.00005140588660158115,
        0.034353122167663945,
        0.2939678172696909,
        0.6305507872508098,
        0.7655438233080649,
        0.7265627102304902,
        0.6520409083583577,
        0.5563141595733513,
        0.4720240603482563,
        0.3955228205890224,
        0.31634138696308517,
        0.23941783804323555,
        0.1567975215165131,
        0.08468805676426536,
        0.0340269959975811,
        0.02544673323072237
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M1 Mark III / prf-solomatov-pred-olympus-e-m1-mark-iii-9cc4ad06c4de@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M1 Mark III / prf-solomatov-pred-olympus-e-m1-mark-iii-9cc4ad06c4de@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2705364 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2705364; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01790067436396729,
        0.03074040313983626,
        0.05849421002127625,
        0.09240627139268505,
        0.1307437002931953,
        0.16482044560362302,
        0.21852851224456302,
        0.31316828345464787,
        0.43242325247175606,
        0.5478280556701427,
        0.6862072164780783,
        0.8497185591291966,
        0.9622054555320466,
        1,
        0.9826580083123749,
        0.9205270344397278,
        0.8270342179462726,
        0.6894025351117262,
        0.5363123409640994,
        0.3945993958668778,
        0.2778448075748772,
        0.1884564886647416,
        0.13643934790290696,
        0.09680386816709322,
        0.06684712297494902,
        0.041946115199285566,
        0.02990953527880167,
        0.015157006598742348,
        0.0074076094751020565,
        0.00850536748474512,
        0.0036427234930308827
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M1 Mark III / prf-solomatov-pred-olympus-e-m1-mark-iii-9cc4ad06c4de@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M1 Mark III / prf-solomatov-pred-olympus-e-m1-mark-iii-9cc4ad06c4de@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2705364 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2705364; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04500468144027939,
        0.10622538039243518,
        0.2532130241993314,
        0.4389723896673423,
        0.5659009286735537,
        0.6489038073989304,
        0.7115797356658845,
        0.7233485031958731,
        0.6831470367758276,
        0.593894463000173,
        0.4677170244004134,
        0.34705987807925287,
        0.2394527686477679,
        0.1656764856780825,
        0.13166267459757727,
        0.10796926402509976,
        0.09884548622662237,
        0.09148759279712453,
        0.08002845088498257,
        0.05746860681224412,
        0.031770844884459165,
        0.01323242084983758,
        0.0003465854872024615,
        0.000010664152032776364,
        0.00002812266667258084,
        0.00005290587699104446,
        0.000011772985077054326,
        0.00002829221502171242,
        0.00002055636505845424,
        0.00007468563564828984,
        0.0005344620908683637
      ],
      "range": 1
    }
  }
]
