    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark II / prf-solomatov-pred-olympus-e-m10-mark-ii-7f5e8ad5f417@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark II / prf-solomatov-pred-olympus-e-m10-mark-ii-7f5e8ad5f417@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000497184377358 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26350772; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.019341890932075917,
        0.031985638978622714,
        0.03666953035795398,
        0.0007363109990027599,
        0.014776711285726277,
        0.038741804604434354,
        0.06857588064790564,
        0.09355614397744916,
        0.12839103474210675,
        0.12072568902810318,
        0.09903630572948678,
        0.07731851718223126,
        0.05157469514336459,
        0.015600757351625217,
        0.00004103784975340465,
        0.00008195007003624374,
        0.02147137486413789,
        0.22935841560123832,
        0.5297211622098023,
        0.6701906520156833,
        0.6418786427459,
        0.5778082719089552,
        0.4930114295776058,
        0.4242661946262812,
        0.3592117940961084,
        0.29242914021646116,
        0.23078248672919102,
        0.1589330927212394,
        0.09217893513484827,
        0.036269308036465366,
        0.02484922062787599
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark II / prf-solomatov-pred-olympus-e-m10-mark-ii-7f5e8ad5f417@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark II / prf-solomatov-pred-olympus-e-m10-mark-ii-7f5e8ad5f417@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000497184377358 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26350772; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.025467242288005832,
        0.042639749031946714,
        0.08623537445036489,
        0.13939900393686536,
        0.20157127913299153,
        0.24798535525090326,
        0.30045513219812336,
        0.39032486612504136,
        0.49767775383709184,
        0.6066993298824684,
        0.7338782081982266,
        0.886521711401703,
        0.9826814897345467,
        1,
        0.962547526402923,
        0.8870529216718618,
        0.7867695638236762,
        0.6578916615968062,
        0.5249008800878054,
        0.39539384787638177,
        0.2878062241086017,
        0.2029855433507279,
        0.1492755913405742,
        0.10750273298821023,
        0.07662711545747122,
        0.05206307533199815,
        0.037568993551055474,
        0.02210087034726679,
        0.013094789974274755,
        0.008480279752747646,
        0.0034797599532513557
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark II / prf-solomatov-pred-olympus-e-m10-mark-ii-7f5e8ad5f417@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus E M10 Mark II / prf-solomatov-pred-olympus-e-m10-mark-ii-7f5e8ad5f417@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000497184377358 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26350772; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06796590769712553,
        0.1568427320903817,
        0.35578508450747254,
        0.5790839404523301,
        0.7188727853452022,
        0.8082608484234668,
        0.8726741115394364,
        0.8745036937365065,
        0.8126526631427217,
        0.6799087328447151,
        0.512827416972831,
        0.35600100348140856,
        0.2211125312060628,
        0.12953059971070294,
        0.08852005964983717,
        0.06284701971056965,
        0.05464869736210059,
        0.05256827396762363,
        0.04546578068717133,
        0.03234456049268882,
        0.020335971510309702,
        0.012747577192954133,
        0.010045450654679478,
        0.002442079472318776,
        0.000013167539331248055,
        0.0000065976375306079195,
        0.000005586367295390469,
        0.0001388838922481845,
        0.00001547991827559449,
        0.000023727126311600053,
        0.000053861501612606586
      ],
      "range": 1
    }
  }
]