    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus SP 560UZ / prf-solomatov-pred-olympus-sp-560uz-9e9bb6df1c17@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus SP 560UZ / prf-solomatov-pred-olympus-sp-560uz-9e9bb6df1c17@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000497026660377 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26342413; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015125874725295666,
        0.029507357129689694,
        0.03562285196012334,
        0.0001499669682482576,
        0.015374340818912277,
        0.0390646382065809,
        0.07109233723940371,
        0.10145009543225812,
        0.13485311572444028,
        0.13260053283653248,
        0.10747936128706205,
        0.08630053493327787,
        0.06254152980185633,
        0.021495713775347765,
        0.000048533747965052915,
        0.000007235747579043313,
        0.00008232488468311539,
        0.2246872306102483,
        0.5471799033748351,
        0.6977116436215027,
        0.6650887025168626,
        0.5870251453301613,
        0.5032139681896018,
        0.4306293862622662,
        0.3704454200911663,
        0.30679954618607463,
        0.24431973960959782,
        0.1728788611054331,
        0.09609824189115053,
        0.041950046077040656,
        0.027054559070629883
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus SP 560UZ / prf-solomatov-pred-olympus-sp-560uz-9e9bb6df1c17@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus SP 560UZ / prf-solomatov-pred-olympus-sp-560uz-9e9bb6df1c17@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000497026660377 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26342413; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.021415105764988198,
        0.04169260081664112,
        0.08099473542642321,
        0.13707132852679926,
        0.18847094443543122,
        0.23381792464410067,
        0.3002371094395418,
        0.4028826222385897,
        0.5275019683403086,
        0.6385052717618758,
        0.7650413756704824,
        0.9077729403863781,
        0.991590826433519,
        1,
        0.959795820105352,
        0.8809949214875369,
        0.7796454801670165,
        0.6453889738474924,
        0.49847613978368605,
        0.3662331592627152,
        0.259427029330988,
        0.17960182790504073,
        0.1307804513311033,
        0.08920833462184324,
        0.058916098892497056,
        0.036792206837403536,
        0.024591391663874734,
        0.011111612418833303,
        0.005357889296134672,
        0.004752150529416495,
        0.0008451089058762927
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus SP 560UZ / prf-solomatov-pred-olympus-sp-560uz-9e9bb6df1c17@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Olympus SP 560UZ / prf-solomatov-pred-olympus-sp-560uz-9e9bb6df1c17@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000497026660377 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26342413; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06230817171152847,
        0.1505186814409032,
        0.3462319014912242,
        0.5690633394756929,
        0.7023290711654036,
        0.7783043261830266,
        0.8318967623412677,
        0.8252110526739568,
        0.7692837671451485,
        0.6525537934057994,
        0.5127962749653951,
        0.38534919511962795,
        0.27049351509527764,
        0.19009074833045855,
        0.14251190220065205,
        0.10465507013347639,
        0.07853427528775418,
        0.06955800052155367,
        0.06510794849984006,
        0.04395563071485143,
        0.016190845095828285,
        0.001543662617267496,
        0.00007819968651731628,
        0.0003195468457702407,
        0.003305957280043024,
        0.006443376694458476,
        0.008471777123006227,
        0.00637686204871753,
        0.002788260212666524,
        0.0016858250609008368,
        0.0006738652318167338
      ],
      "range": 1
    }
  }
]